CPC7593
1.6.5 Ringing Test Return Switch, SW7
Parameter
Test Conditions
(differential) = T to T
RINGING
Symbol
Minimum
Typical
Maximum
Unit
V
SW7
TESTin
All-Off state.
+25° C,
V
V
(differential) = -320 V to gnd
(differential) = +260 to -60 V
0.1
0.3
0.1
SW
SW
Off-State
Leakage Current
+85° C,
V
V
(differential) = -330 V to gnd
I
-
1
μA
SW
SW
SW
(differential) = +270 V to -60 V
-40° C,
V
V
(differential) = -310 V to gnd
SW
SW
(differential) = +250 V to -60 V
(on) = 10 mA, 40 mA
I
SW
+25° C
+85° C
-40° C
60
85
45
-
100
-
On Resistance
DC current limit
R
-
Ω
ON
V
(on) = 10V
SW
+25° C
-
60
-
120
80
I
+85° C
-
mA
SW
-40° C
210
Logic inputs = GND
+25°C, V (T
, T
SW RINGING TESTin
)= 320V
)= 330V
0.1
0.3
0.1
Logic input to switch
output isolation
+85°C, V (T , T
SW RINGING TESTin
I
-
1
-
μA
SW
-40°C, V (T , T
SW RINGING TESTin
)= 310V
100V Square Wave, 100Hz
PP
(Not production tested - limits are
guaranteed by design and quality
control sampling audits.)
dv/dt sensitivity
-
500
V/μs
R04
www.clare.com
9