CPC7591
1.3 Absolute Maximum Ratings
1.4 ESD Rating
ESD Rating (Human Body Model)
1000 V
Parameter
+5 V power supply (V
Battery Supply
Minimum Maximum
Unit
)
-0.3
-
7
V
V
V
V
DD
-85
+5
D
to F
Separation
-5
GND
GND
1.5 General Conditions
V
+ 0.3
Unless otherwise specified, minimum and maximum
values are guaranteed by production testing
requirements.
Logic input voltage
-0.3
DD
Logic input to switch output
isolation
-
-
-
320
320
465
V
V
V
Switch open-contact
isolation (SW1, SW2, SW3)
Typical values are characteristic of the device at
+25°C and are the result of engineering evaluations.
They are provided for information purposes only and
are not part of the manufacturing testing requirements.
Switch open-contact
isolation (SW4)
Operating relative humidity
Operating temperature
Storage temperature
5
95
%
Specifications cover the operating temperature range
-40
-40
+110
+150
°C
°C
T = -40°C to +85°C. Also, unless otherwise specified
A
all testing is performed with V = 5V , logic low
DD
dc
input voltage is 0V and logic high voltage is 5V .
dc
dc
Absolute maximum electrical ratings are at 25°C.
Absolute maximum ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
4
www.clare.com
R05