欢迎访问ic37.com |
会员登录 免费注册
发布采购

CPC7582MCTR 参数 Datasheet PDF下载

CPC7582MCTR图片预览
型号: CPC7582MCTR
PDF下载: 下载PDF文件 查看货源
内容描述: 线卡接入交换机 [Line Card Access Switch]
分类和应用:
文件页数/大小: 19 页 / 566 K
品牌: CLARE [ CLARE ]
 浏览型号CPC7582MCTR的Datasheet PDF文件第8页浏览型号CPC7582MCTR的Datasheet PDF文件第9页浏览型号CPC7582MCTR的Datasheet PDF文件第10页浏览型号CPC7582MCTR的Datasheet PDF文件第11页浏览型号CPC7582MCTR的Datasheet PDF文件第13页浏览型号CPC7582MCTR的Datasheet PDF文件第14页浏览型号CPC7582MCTR的Datasheet PDF文件第15页浏览型号CPC7582MCTR的Datasheet PDF文件第16页  
CPC7582  
2. Functional Description  
2.1 Introduction  
SLIC device during a fault condition. Positive and  
negative surges are reduced by the current limiting  
circuitry and hazardous potentials are diverted to  
ground via diodes and, in xA/C parts, an integrated  
SCR. Power-cross potentials are also reduced by the  
current limiting and thermal shutdown circuits.  
2.1.1 CPC7582xA/B Logic States  
Talk. Break switches SW1 and SW2 closed, ringing  
switches SW3 and SW4 open, and test switches  
SW5 and SW6 open.  
Ringing. Break switches SW1 and SW2 open,  
ringing switches SW3 and SW4 closed, and test  
switches SW5 and SW6 open.  
Test. Break switches SW1 and SW2 open, ringing  
switches SW3 and SW4 open, and loop test  
switches SW5 and SW6 closed.  
All off. Break switches SW1 and SW2 open, ringing  
switches SW3 and SW4 open, and test switches  
SW5 and SW6 open.  
To protect the CPC7582 from an overvoltage fault  
condition, use of a secondary protector is required.  
The secondary protector must limit the voltage seen at  
the tip and ring terminals to a level below the  
maximum breakdown voltage of the switches. To  
minimize the stress on the solid-state contacts, use of  
a foldback or crowbar type secondary protector is  
recommended. With proper selection of the secondary  
protector, a line card using the CPC7582BC will meet  
all relevant ITU, LSSGR, TIA/EIA and IEC protection  
requirements.  
2.1.2 CPC7582xC Logic States:  
Talk. Break switches SW1 and SW2 closed, ringing  
switches SW3 and SW4 open, and test switches  
SW5 and SW6 open.  
Ringing. Break switches SW1 and SW2 open,  
ringing switches SW3 and SW4 closed, and test  
switches SW5 and SW6 open.  
Test/Monitor. Break switches SW1 and SW2  
closed, ringing switches SW3 and SW4 open, and  
test switches SW5 and SW6 closed.  
The CPC7582 operates from a +5 V supply only. This  
gives the device extremely low idle and active power  
consumption and allows use with virtually any range of  
battery voltage. Battery voltage is also used by the  
CPC7582 as a reference for the integrated protection  
circuit. In the event of a loss of battery voltage, the  
CPC7582 enters the all-off state.  
Ringing Test. Break switches SW1 and SW2 open,  
ringing switches SW3 and SW4 closed, and test  
switches SW5 and SW6 closed.  
All off. Break switches SW1 and SW2 open, ringing  
switches SW3 and SW4 open, and test switches  
SW5 and SW6 open.  
2.2 Switch Logic  
The CPC7582 provides, when switching from the  
ringing state to the talk state, the ability to control the  
release timing of the ringing switches SW3 and SW4  
relative to the state of the break switches SW1 and  
SW2 using simple logic-level inputs. This is referred to  
as make-before-break or break-before-make  
operation. When the break switch contacts (SW1 and  
SW2) are closed (or made) before the ringing switch  
contacts (SW3 and SW4) are opened (or broken), this  
is referred to as make-before-break operation.  
Break-before-make operation occurs when the ringing  
contacts (SW3 and SW4) are opened (broken) before  
the break switch contacts (SW1 and SW2) are closed  
(made). With the CPC7582, the make-before-break  
and break-before-make operations can easily be  
selected by applying logic-level inputs to the device.  
The CPC7582 offers break-before-make and make-  
before-break switching from the ringing state to the  
talk state with simple logic-level input control.  
Solid-state switch construction means no impulse  
noise is generated when switching during ring  
cadence or ring trip, eliminating the need for external  
zero-cross switching circuitry. State control is via  
logic-level input so no additional driver circuitry is  
required. The linear break switches SW1 and SW2  
have exceptionally low R and excellent matching  
ON  
characteristics. The ringing switch SW4 has a  
minimum open contact breakdown voltage of 480 V.  
This is sufficiently high, with proper protection, to  
prevent breakdown in the presence of a transient fault  
condition (i.e., passing the transient on to the ringing  
generator).  
The logic sequences for these modes of operation are  
given in “Make-Before-Break Operation for All  
Versions (Ringing to Talk Transition)” on page 13,  
“Break-Before-Make Operation CPC7582xA/B  
(Ringing to Talk Transition)” on page 13, and  
“Break-Before-Make Operation for all Version (Ringing  
to Talk Transition)” on page 14. Logic states and input  
control settings are given in “CPC7582xA/B Truth  
Integrated into the CPC7582 is an over voltage  
clamping circuit, active current limiting, and a thermal  
shutdown mechanism to provide protection to the  
12  
www.clare.com  
R05