CPC7508  
2. Functional Description  
2.1 Introduction  
minimum open contact breakdown voltage of 320 V  
and a minimum contact to ground breakdown voltage  
of 225 V at +25°C, sufficiently high with proper  
protection to prevent breakdown in the presence of a  
transient fault condition.  
The CPC7508 LCAS provides the necessary test  
access functions for line card interfaces supported by  
ringing SLICs in contemporary Fiber In The Loop  
(FITL), Fiber To The Home (FTTH) applications and  
Voice over Internet Protocol (VoIP).  
Integrated into the CPC7508 is a dynamic active  
current limit, a DC current limit and a thermal  
shutdown mechanism to provide protection for the  
SLIC during a fault condition. Positive and negative  
lightning surge currents are reduced by the dynamic  
current limiting circuitry and excess power-cross  
potentials are restricted by the DC current limit and  
thermal shutdown circuits.  
These applications have a different working  
environment than standard traditional Digital Loop  
Carrier (DLC) equipment and therefore have unique  
requirements. Two significant differences are the  
diverse supply voltages and the interface to ringing  
SLICs.  
The once common 5V supply is generally not available  
in the modern short loop products made feasible with  
the advent of broadband services. To support  
To protect the CPC7508 from an over-voltage fault  
condition, use of a secondary protector is required.  
The secondary protector must limit the voltage seen at  
it’s tip and ring line terminals to a level below the  
maximum breakdown voltage of the switches. With  
proper selection of the secondary protector, a line  
interface circuit using the CPC7508 will meet all  
relevant ITU, LSSGR, TIA/EIA and IEC protection  
requirements.  
applications where a 5V supply is not available but a  
12V supply is, the V input power specification for  
DD  
the CPC7508 has been set accordingly.  
Ringing SLICs have replaced the customary standard  
SLIC and ringing relay configuration and for the LCAS  
to be compatible with a ringing SLIC. the LCAS  
internal protection circuits have been removed. This  
was essential so as not to clip the ringing waveform  
output from the ringing SLIC.  
The CPC7508 operates from a single +12.5 V supply  
giving the device extremely low power consumption in  
any state.  
Traditional test access is provided by two pair of test  
access switches, TEST_IN and TEST_OUT,  
State control is via TTL logic-level compatible inputs  
so no additional driver circuitry or level translators are  
required. TTL compatible inputs make state control of  
the CPC7508 with low voltage logic devices possible.  
employing the TEST_IN & OUT state. Supplementing  
the traditional test access switches is the TEST  
BRIDGE switch pair capable of cross connecting the  
test busses thereby providing the means to validate  
the status of SW1 and SW2, the Break Switches.  
2.2.2 Logic States  
The CPC7508 provides eight distinct states enabling  
sufficient configurations to satisfy most design  
requirements. They are defined below.  
2.2 Description  
2.2.1 Overview  
Talk. Break switches SW1 and SW2 closed, all other  
switches open. This provides a path between the  
ringing SLIC and the drop allowing communication  
and signalling to pass between the subscriber and  
the network.  
Test_IN. Test switches SW5 and SW6 closed, all  
other switches open. In this state the SLIC, CODEC  
and digital carrier performance can be tested via the  
Test In or Channel Test bus  
Because the CPC7508 LCAS utilizes solid-state  
switch construction to implement the switching  
functions this means no impulse noise is generated  
when switching large line potentials. To ensure proper  
voice performance the linear break switches SW1 and  
SW2 have exceptionally low R and excellent  
matching characteristics. The switches have a  
ON  
Test_OUT. Test switches SW3 and SW4 closed and  
all other switches open. This state provides the  
R04  
www.clare.com  
9