欢迎访问ic37.com |
会员登录 免费注册
发布采购

CPC7582BB 参数 Datasheet PDF下载

CPC7582BB图片预览
型号: CPC7582BB
PDF下载: 下载PDF文件 查看货源
内容描述: 线卡接入交换机 [Line Card Access Switch]
分类和应用: 电信集成电路光电二极管
文件页数/大小: 12 页 / 148 K
品牌: CLARE [ CLARE ]
 浏览型号CPC7582BB的Datasheet PDF文件第1页浏览型号CPC7582BB的Datasheet PDF文件第3页浏览型号CPC7582BB的Datasheet PDF文件第4页浏览型号CPC7582BB的Datasheet PDF文件第5页浏览型号CPC7582BB的Datasheet PDF文件第6页浏览型号CPC7582BB的Datasheet PDF文件第7页浏览型号CPC7582BB的Datasheet PDF文件第8页浏览型号CPC7582BB的Datasheet PDF文件第9页  
CPC7582  
Absolute Maximum Ratings (@ 25˚ C)  
Absolute Maximum Ratings are stress ratings. Stresses in  
excess of these ratings can cause permanent damage to  
the device. Functional operation of the device at these or  
any other conditions beyond those indicated in the opera-  
tional sections of this data sheet is not implied. Exposure of  
the device to the absolute maximum ratings for an extend-  
ed period may degrade the device and effect its reliability.  
Parameter  
Min Max Units  
Operating Temperature Range  
Storage Temperature Range  
Relative Humidity Range  
Pin Soldering Temperature  
(t=10 s max)  
-40  
-40  
5
+110  
+150  
95  
˚C  
˚C  
%
˚C  
-
+260  
+5V Power Supply  
Battery Supply  
Logic Input Voltage  
Logic Input to Switch Output Isolation  
Switch Isolation (SW1, SW2, SW3, SW5, SW6)  
Switch Isolation (SW4)  
-
-
-
-
-
-
7
-85  
7
330  
330  
480  
V
V
V
V
V
V
Power Supply Specifications  
Supply  
Min  
+4.5  
-19  
Typ  
+5.0  
-
Max  
+5.5  
-72  
Unit  
V
V
VDD  
Electrical Characteristics TA = -40oC to +85oC  
1
VBAT  
1 VBAT is used only as a reference for internal protection circuitry.  
If VBAT rises above -10V, the device will enter an all off state and will remain in the all off state  
until the battery voltage drops below -15V.  
(unless otherwise specified)  
Minimum and maximum values are production testing  
requirements. Typical values are characteristic of the  
device and are the result of engineering evaluations.  
Typical values are provided for information purposes  
only and are not part of the testing requirements.  
ESD Rating (HBM)  
1000V  
Table 1. Break Switch, SW1 and SW2  
Parameters  
Conditions  
Symbol  
Min  
Typ  
Max  
Units  
Off-state Leakage Current:  
+25˚C  
Vsw (differential)= -320V to Gnd  
Vsw (differential)= -60V to +260V  
Vsw (differential)= -330V to Gnd  
Vsw (differential)= -60V to +270V  
Vsw (differential)= -310V to Gnd  
Vsw (differential)= -60V to +250V  
Isw  
Isw  
Isw  
-
-
-
0.1  
0.3  
0.1  
1
1
1
µA  
µA  
µA  
+85˚C  
-40˚C  
RDSON (SW1,SW2):  
+25˚C  
+85˚C  
-40˚C  
RDSON Match  
TLINE= +/-10 mA, +/-40mA, TBAT= -2V  
TLINE= +/-10 mA, +/-40mA, TBAT= -2V  
TLINE= +/-10 mA, +/-40mA, TBAT= -2V  
Per ON-resistance Test Condition of  
SW1, SW2RON SW1-RONSW2  
V  
V  
V  
-
-
-
-
14.5  
20.5  
10.5  
0.15  
-
28  
-
Magnitude  
0.8  
dc Current Limit:  
+25˚C  
+85˚C  
Vsw (on) = +/- 10V  
Vsw (on) = +/- 10V  
Vsw (on) = +/- 10V  
Break switches in ON state, Ringing  
access switches OFF, Apply +/- 1000V  
at 10/1000ms pulse, Appropriate  
secondary protection in place.  
lsw  
lsw  
lsw  
Isw  
-
80  
-
300  
160  
400  
2.5  
-
-
mA  
mA  
mA  
A
-40˚C  
425  
-
Dynamic Current Limit:  
(t=<0.5µs)  
-
Rev. 1.0  
2