CPC2014N
Absolute Maximum Ratings (@ 25˚C)
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter
Blocking Voltage
Ratings
60
Units
VP
Reverse Input Voltage
5
50
V
Input Control Current
Peak (10ms)
mA
A
1
Input Power Dissipation
70
mW
mW
Vrms
°C
Total Power Dissipation 1
Isolation Voltage, Input to Output
Operational Temperature
600
1500
-40 to +85
-40 to +125
Storage Temperature
°C
1
Derate Linearly 5.0 mW / ºC
Electrical Characteristics
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics @ 25°C
Load Current
Continuous 1
IF=2mA
t <10ms
IL=400mA
VL=60VP
IL
-
-
-
-
-
-
-
-
400
1
mA
AP
Ω
Peak
On-Resistance 2
ILPK
RON
ILEAK
2
Off-State Leakage Current
Switching Speeds
1
µA
Turn-On
tON
tOFF
-
-
-
-
0.47
0.22
40
2
1
-
IF=5mA, VL=10V
ms
Turn-Off
Output Capacitance
Capacitance Input to Output
Input Characteristics @ 25°C
Input Control Current 3
Input Dropout Current
Input Voltage Drop
50V; f=1MHz
-
COUT
pF
pF
1
-
-
IL=400mA
-
IF
IF
-
0.25
0.2
1.2
-
2
-
mA
mA
V
0.1
0.9
-
IF=5mA
VR=5V
VF
1.4
10
Reverse Input Current
IR
µA
1
2
3
Load current derates linearly from 400mA @ 25oC to 200mA @80oC, and must be derated for both poles operating simultaneously.
Measurement taken within 1 second of on time.
For applications requiring high temperature operation (greater than 60oC) an LED drive current of 4mA is recommended.
R01
2