CPC1945Y
Absolute Maximum Ratings @ 25ºC
Parameter
Blocking Voltage
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Ratings Units
400
VP
Reverse Input Voltage
5
V
Input Control Current
Peak (10ms)
100
1
mA
A
Input Power Dissipation1
PMAX , Total Package Dissipation 2
150
1600
3750
mW
mW
Vrms
°C
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
-40 to +85
-40 to +125
°C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 16.6 mW / ºC
Electrical Characteristics @ 25ºC
Parameters
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics
Operating Voltage Range
Load Current, Continuous
Non-Repetitive Single Cycle Surge Current
Off State Leakage Current
On-State Voltage Drop
Critical Rate of Rise 3
Switching Speeds
VL
-
IL
20
-
-
-
-
-
-
120
1
Vrms
Arms
A
VL=120Vrms
0.005
-
ITSM
ILEAK
-
-
10
1
VL=400VP
IL=1Arms
-
-
-
mA
Vrms
V/µs
1.6
-
dV/dt
1000
Turn-on
ton
toff
-
-
-
-
0.5
0.5
10
-
IF=5 mA
cycles
Turn-off
-
-
Zero-Cross Turn-On Voltage
1st half-cycle
2
1
-
V
V
Subsequent half-cycle
-
-
Operating Frequency 1
-
-
-
20
0.25
400
-
Hz
-
Load Power Factor for Guaranteed Turn-On 2
Input Characteristics
Input Control Current 4
PF
-
-
IF
VF
-
-
0.8
1.2
-
5
1.4
-
mA
V
Input Voltage Drop
IF=5mA
-
0.9
0.8
-
Input Drop-out Voltage
V
Reverse Input Current
VR=5V
IR
-
10
µA
Common Characteristics
Input to Output Capacitance
-
CI/O
-
3
-
pF
1 Zero Cross 1st half-cycle @ <100Hz
2 Snubber circuits may be required at low power factors.
3 Tested in accordance with EIA/NARM standard RS-443.
4 For high noise environments, use IF=10mA.
R05
2
www.clare.com