CPC1998
1 .Specifications
1.1 Absolute Maximum Ratings @ 25°C
Symbol
Blocking Voltage
Min
Max
Units
Absolute maximum ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
-
-
-
-
-
800
5
50
1
VP
Reverse Input Voltage
Input Control Current
Peak (10ms)
V
mA
A
1
150
Input Power Dissipation
Total Power Dissipation
mW
W
2
-
3.5
2
I t for Fusing
(1/2 Sine Wave, 60Hz)
A2s
-
200
Isolation Voltage, Input to Output
ESD, Human Body Model
Operational Temperature
Storage Temperature
-
2500
8
+85
+125
Vrms
-
kV
°C
- 40
- 40
°C
1 Derate linearly 1.33mW / °C.
2 Free air, no heat sink.
1.2 Electrical Characteristics @ 25°C
Parameter
Output Characteristics
Load Current
Conditions
Symbol
Minimum
Typical Maximum Units
No Heat Sink, V =20-240V
L
T =25°C
Continuous
Continuous
0.1
0.1
-
-
5
50
150
100
1.1
-
rms
IL
Arms
C
Maximum Surge Current
1/2 Sine Wave, 60Hz
V =800V
IP
-
-
A
μAP
VP
Off-State Leakage Current
1
ILEAK
L
-
-
-
0.85
-
I =2A
L
On-State Voltage Drop
P
-
I =0mA
F
Off-State dV/dt
Switching Speeds
Tur n-On
dV/dt
1000
V/μs
ton
toff
-
-
-
-
0.5
0.5
I =5mA
F
cycles
V
Tur n-Off
st
Zero-Cross Turn-On Voltage
1 half-cycle
subsequent half-cycle
-
-
-
5
-
20
5
-
-
IH
Holding Current
Latching Current
-
-
44
48
-
50
75
500
-
mA
mA
Hz
-
-
IL
2
-
Operating Frequency
-
20
0.25
3
f=60Hz
Load Power Factor for Guaranteed Turn-On
Input Characteristics
Input Control Current
Input Dropout Voltage
Input Voltage Drop
PF
-
4
I =1A Resistive, f=60Hz
L
IF
-
-
-
5
-
mA
V
-
I =5mA
-
VF
0.8
F
0.9
-
1.2
-
1.4
10
V
V =5V
R
Reverse Input Current
Input/Output Characteristics
Capacitance, Input-to-Output
IR
μA
-
C
-
-
3
pF
I/O
1 Tested at a peak value equivalent.
2 Zero-cross first half-cycle @ < 100Hz.
3 Snubber circuits may be required at low power factors.
4 For high-noise environments, or high-frequency operation (>60Hz), or for applications with a high inductive load, use IF ≥ 10mA.
R01 www.clare.com
2