CPC1963
Absolute Maximum Ratings
Parameter
Blocking Voltage
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Ratings Units
600
VP
Reverse Input Voltage
5
50
V
Input Control Current
Peak (10ms)
mA
A
1
Input Power Dissipation 1
Total Package Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
150
mW
mW
Vrms
°C
800
3750
-40 to +85
-40 to +125
°C
1
Derate Linearly 1.33 mW/˚C
Derate Linearly 6.67 mW/˚C
2
Electrical absolute maximum ratings are at 25°C
Electrical Characteristics
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics @ 25°C
Operating Voltage Range
Load Current, Continuous
Off State Leakage Current
On-State Voltage Drop
Critical Rate of Rise 3
Switching Speeds
VT
VL=120Vrms
V = 600V
IL=500 mArms
-
-
20
0.005
-
-
-
-
-
-
260
0.5
1
Vrms
Arms
mA
IL
ILEAK
VON
dV/dt
-
1.4
-
Vrms
V/µs
1000
Turn-on
tON
-
-
-
0.5
0.5
10
-
IF=5 mA
cycles
V
Turn-off
Zero-Cross Turn-On Voltage 1
tOFF
-
-
1st half cycle
2
1
-
Subsequent half cycle
-
-
Operating Frequency
-
-
20
0.25
500
-
Hz
-
Load Power Factor for Guaranteed Turn-On 2
Input Characteristics @ 25°C
Input Control Current 4
PF
IF
-
-
-
0.23
5
-
mA
V
Input Drop-out Voltage
-
0.8
0.9
-
-
1.2
-
Input Voltage Drop
IF=5mA
VR=5V
VF
IR
1.4
10
V
Reverse Input Current
µA
Common Characteristics @ 25°C
Input to Output Capacitance
-
CI/O
-
3
-
pF
1 Zero Cross 1st half cycle @ <100Hz
2 Snubber circuits may be required at low power factors.
3 Tested in accordance with EIA/NARM standard RS-443.
4 For high noise environments use at least 10mA LED current.
R04
2
www.clare.com