CPC1979
Absolute Maximum Ratings
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter
Blocking Voltage
Ratings
600
Units
VP
Reverse Input Voltage
Input Control Current
Peak (10ms)
5
100
V
mA
A
1
Input Power Dissipation
Isolation voltage Input to Output
Operational Temperature
Storage Temperature
150
mW
Vrms
°C
2500
-40 to +85
-40 to +125
°C
Electrical absolute maximum ratings are at 25°C
Electrical Characteristics
Parameter
Output Characteristics
Load Current 1
Conditions
TA=25°C
Symbol
Min
Typ
Max
Units
Peak
t ≤ 10ms
No Heat Sink
TC=25ºC
20
1.4
14.5
1.7
0.75
1
AP
Continuous
IL
-
-
Continuous
Arms
Continuous
On-Resistance 2
TC=99ºC
IL(99)
RON
Ω
IF=10mA, IL=1A
VL=600V
-
-
0.59
-
Off-State Leakage Current
Switching Speeds
Turn-On
ILEAK
µA
TON
TOFF
COUT
-
-
-
8
25
5
IF=20mA, VL=10V
ms
pF
Turn-Off
0.2
700
Output Capacitance
Input Characteristics
Input Control Current 3
Input Dropout Current
Input Voltage Drop
Reverse Input Current
Common Characteristics
Capacitance Input to Output
V=25V, f=1MHz
-
TA=25°C
IL=1A
-
IF
IF
-
-
-
10
-
mA
mA
V
0.6
0.9
-
IF=5mA
VR=5V
TA=25°C
-
VF
IR
1.2
-
1.4
10
µA
CI/O
-
1
-
pF
1
2
3
Higher load currents are possible with proper heat sinking.
Measurement taken within 1 second of on time.
For applications requiring high temperature operation (greater than 60oC) an LED drive current of 20mA is recommended.
R04
2
www.clare.com