CPC1977
Absolute Maximum Ratings
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter
Blocking Voltage
Ratings
600
Units
VP
Reverse Input Voltage
Input control Current
Peak (10ms)
5
100
V
mA
A
1
Input Power Dissipation
Isolation voltage Input to Output
Operational Temperature
Storage Temperature
150
mW
Vrms
°C
2500
-40 to +85
-40 to +125
°C
Electrical absolute maximum ratings are at 25°C
Electrical Characteristics
Parameter
Conditions
TA = 25°C
Symbol
Min
Typ
Max
Units
Output Characteristics
Load Current 1
Peak
t ≤ 10ms
No Heat Sink
TC=25°C
-
-
-
-
-
-
-
15
1.25
12.25
1.4
1
AP
Continuous
IL
-
Continuous
-
Arms
Continuous
On-Resistance 2
TC=99°C
IL(99)
RON
-
0.57
-
Ω
IL=1A, IF=10mA
VL=600V
Off-State Leakage Current
Switching Speeds
Turn-On
ILEAK
1
µA
IF=20mA, VL=10V
TON
TOFF
COUT
-
-
-
7.5
20
5
ms
pF
Turn-Off
0.085
2450
Output Capacitance
Input Characteristics
Input Control Current 3
Input Dropout Current
Input Voltage Drop
Reverse Input Current
Input/Output Characteristics
Capacitance Input/Output
V=25V, f=1MHz
-
TA = 25°C
IL=1A
IF
IF
-
-
-
10
-
mA
mA
V
-
IF=5mA
VR=5V
TA = 25°C
-
0.6
0.9
-
VF
IR
1.2
-
1.4
10
µA
CI/O
-
1
-
pF
1
2
3
Higher load currents are possible with proper heatsinking.
Measurement taken within 1 second of on time.
For applications requiring high temperature operation (greater than 60ºC) an LED drive current of 20mA is recommended.
R04
2
www.clare.com