CPC1909  
Absolute Maximum Ratings  
Absolute Maximum Ratings are stress ratings. Stresses in  
excess of these ratings can cause permanent damage to  
the device. Functional operation of the device at conditions  
beyond those indicated in the operational sections of this  
data sheet is not implied.  
Parameter  
Blocking Voltage  
Ratings  
60  
Units  
VP  
Reverse Input Voltage  
Input Control Current  
Peak (10ms)  
5
100  
V
mA  
A
1
Input Power Dissipation  
Isolation voltage Input to Output  
Operational Temperature  
Storage Temperature  
150  
mW  
Vrms  
°C  
2500  
-40 to +85  
-40 to +125  
°C  
Electrical absolute maximum ratings are at 25°C  
Electrical Characteristics  
Parameter  
Conditions  
TA = 25°C  
Symbol  
Min  
Typ  
Max  
Units  
Output Characteristics,  
Load Current 1  
Peak  
t 10ms  
No Heat Sink  
TC=25°C  
25  
6.5  
15  
AP  
IL  
Continuous  
-
-
Continuous  
Arms  
Continuous  
On-Resistance 2  
TC=99°C  
IL(99)  
RON  
7.85  
0.1  
1
Ω
IF=10mA, IL=1A  
VL=60V  
-
-
0.05  
-
Off-State Leakage Current  
Switching Speeds  
Turn-On  
ILEAK  
µA  
TON  
TOFF  
COUT  
-
-
-
15  
0.3  
25  
10  
-
IF=20mA, VL=10V  
ms  
pF  
Turn-Off  
Output Capacitance  
Input Characteristics,  
Input Control Current 3  
Input Dropout Current  
Input Voltage Drop  
Reverse Input Current  
Common Characteristics,  
Capacitance Input to Output  
V=25V, f=1MHz  
4000  
TA = 25°C  
IL=1A  
IF  
IF  
-
-
-
10  
-
mA  
mA  
V
-
IF=5mA  
VR=5V  
TA = 25°C  
-
0.6  
0.9  
-
VF  
IR  
1.2  
-
1.4  
10  
µA  
CI/O  
-
1
-
pF  
1
2
3
Proper heat sinking required for maximum continuous load current.  
Measurement taken within 1 second of on time.  
For applications requiring high temperature operation (TC > 60°C) an LED drive current of 20mA is recommended.  
R03  
2
www.clare.com