CPC1727
Absolute Maximum Ratings
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter
Blocking Voltage
Ratings
250
Units
VP
Reverse Input Voltage
Input Control Current
Peak (10ms)
5
100
V
mA
ADC
mW
Vrms
°C
1
Input Power Dissipation
Isolation voltage, Input to Output
Operational Temperature
Storage Temperature
150
2500
-40 to +85
-40 to +125
°C
Electrical absolute maximum ratings are at 25°C
Electrical Characteristics
Parameter
Conditions
TA=25°C
Symbol
Min
Typ
Max
Units
Output Characteristics
Load Current 1
Peak
t ≤ 10ms
No Heat Sink
TC=25ºC
30
3.4
20
AP
IL
Continuous
-
-
Continuous
ADC
Continuous
On-Resistance 2
TC=99ºC
IL(99)
RON
4.2
0.09
1
Ω
IF=10mA, IL=1A
VL=250V
-
-
0.0675
-
Off-State Leakage Current
Switching Speeds
Turn-On
ILEAK
µA
IF=20mA, VL=10V
TON
TOFF
COUT
-
-
-
5.5
0.125
700
20
5
ms
pF
Turn-Off
Output Capacitance
Input Characteristics
Input Control Current 3
Input Dropout Current
Input Voltage Drop
Reverse Input Current
Common Characteristics
Capacitance Input to Output
V=25V, f=1MHz
-
TA=25°C
IL=1A
-
IF
IF
-
-
-
10
-
mA
mA
V
0.6
0.9
-
IF=5mA
VR=5V
TA=25°C
-
VF
IR
1.2
-
1.4
10
µA
CI/O
-
1
-
pF
1
2
3
Higher load currents possible with proper heatsinking.
Measurement taken within 1 second of on time.
For applications requiring high temperature operation (greater than 60oC) an LED drive current of 20mA is recommended.
R02
2
www.clare.com