CPC1726
Absolute Maximum Ratings @ 25ºC
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter
Blocking Voltage
Ratings
250
Units
VP
Reverse Input Voltage
Input control Current
Peak (10ms)
5
50
V
mA
A
1
Input Power Dissipation 1
Total Power Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
150
mW
mW
Vrms
°C
1600
2500
-40 to +85
-40 to +125
°C
1
2
Derate linearly 3.33 mW / ºC
Derate linearly 16.667 mW / ºC
Electrical Characteristics @ 25ºC
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics
Load Current, Continuous
Peak Load Current
Free air
t=10ms
IL=1A
IL
-
-
-
-
-
1
3
ADC
A
ILPK
RON
ILEAK
-
0.64
-
On-Resistance1
0.75
1
Ω
µA
Off-State Leakage Current
Switching Speeds
VL=250VP
Turn-On
ton
toff
-
-
-
0.67
0.04
60
5
2
-
IF=10mA, VL=10V
VL=50V, f=1MHz
ms
pF
Turn-Off
Output Capacitance
COFF
Input Characteristics
Input Control Current
IL=1A
-
IF
IF
-
1.8
-
10
-
mA
mA
V
Input Dropout Current
0.6
0.9
-
Input Voltage Drop
IF=5mA
VR=5V
VF
IR
1.2
-
1.4
10
Reverse Input Current
µA
Input/Output Characteristics
Input to Output Capacitance
Measurement taken within 1 second of on-time.
f=1MHz
CI/O
-
2
-
pF
1
Thermal Characteristics
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Thermal Resistance (junction to case)
-
RθJC
-
1.5
-
°C/W
R02
2
www.clare.com