CPC1718
1 Specifications
1.1 Absolute Maximum Ratings @ 25°C
Absolute maximum ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Symbol
Blocking Voltage
Ratings
Units
100
5
VP
Reverse Input Voltage
Input Control Current
Peak (10ms)
V
100
mA
ADC
1
Input Power Dissipation
Isolation Voltage, Input to Output
Operational Temperature
Storage Temperature
150
mW
Vrms
°C
2500
-40 to +85
-40 to +125
°C
1.2 Electrical Characteristics @ 25°C
Parameter
Conditions
Symbol
Minimum
Typical Maximum Units
Output Characteristics
1
Load Current
Peak
t≤10ms
No Heat Sink
AP
40
Continuous
Continuous
Continuous
IL
6.75
-
-
T =25°C
C
ADC
32
8.5
T =99°C
C
IL(99)
RON
2
I =10mA, I =1A
L
On-Resistance
F
-
-
0.03
-
0.075
1
Ω
V =100V
L
Off-State Leakage Current
Switching Speeds
Tur n-On
ILEAK
P
μA
ton
toff
-
-
-
7.5
20
5
I =20mA, V =10V
L
ms
pF
F
Tur n-Off
0.19
1600
V =25V, f=1MHz
L
Output Capacitance
Input Characteristics
Cout
-
3
I =1A
L
IF
IF
Input Control Current
-
-
-
10
-
mA
mA
V
Input Dropout Current
-
0.6
0.9
-
I =5mA
F
Input Voltage Drop
VF
IR
1.2
-
1.4
10
V =5V
R
Reverse Input Current
μA
Input/Output Characteristics
Input-to-Output Capacitance
-
C
-
1
-
pF
I/O
1 Higher load currents possible with proper heat sinking.
2 Measurement taken within 1 second of on-time.
3 For applications requiring high temperature operation (> 60ºC) a LED drive current of 20mA is recommended.
R03
www.clare.com
2