CPC1030N
Absolute Maximum Ratings (@ 25˚C)
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter
Blocking Voltage
Ratings
350
Units
VP
Reverse Input Voltage
Input Control Current
Peak (10ms)
5
50
V
mA
A
1
Input Power Dissipation
Total Power Dissipation 1
Isolation voltage, Input to Output
Operational Temperature
70
mW
mW
Vrms
°C
400
1500
-40 to +85
-40 to +125
Storage Temperature
°C
1
Derate Linearly 3.33 mw / ºC
Electrical Characteristics
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics @ 25°C
Load Current
Continuous 1
-
IL
120
350
30
mA
Peak
On-Resistance 2
t=10ms
IL=120mA
VL=350V
ILPK
RON
ILEAK
-
-
-
-
25
-
Ω
µA
Off-State Leakage Current
Switching Speeds
Turn-On
1
tON
tOFF
-
-
-
-
-
2
1
-
IF=5mA, VL=10V
50V; f=1MHz
ms
pF
Turn-Off
Output Capacitance
Input Characteristics @ 25°C
Input Control Current 3
Input Dropout Current
Input Voltage Drop
Reverse Input Current
COUT
25
IL=120mA
-
IF
IF
-
0.85
0.6
1.2
-
2
-
mA
mA
V
0.3
0.9
-
IF=5mA
VR=5V
VF
IR
1.4
10
µA
Input/Output Characteristics @ 25°C
Capacitance Input to Output
-
-
-
1
-
pF
1
2
3
Load current derates linearly from 120mA @ 25oC to 80mA @85oC.
Measurement taken within 1 second of on time.
For applications requiring high temperature operation (greater than 60oC) an LED drive current of 4mA is recommended.
R12
2
www.clare.com