CPC1008N
Absolute Maximum Ratings (@ 25˚C)
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter
Ratings
100
Units
VP
Blocking Voltage
Reverse Input Voltage
Input Control Current
Peak (10ms)
5
V
50
mA
A
1
70
Input Power Dissipation
mW
mW
pF
Total Power Dissipation 1
Capacitance Input to Output
Isolation Voltage, Input to Output
Operational Temperature
400
1
1500
Vrms
°C
-40 to +85
-40 to +125
Storage Temperature
Derate Linearly 3.33 mw / ºC
°C
1
Electrical Characteristics
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics @ 25°C
Load Current
Continuous 1
-
IL
150
350
8
mA
Peak
On-Resistance 2
t=10ms
IL=150mA
VL=100V
ILPK
RON
ILEAK
-
-
-
-
4.7
-
Ω
µA
Off-State Leakage Current
Switching Speeds
Turn-On
1
TON
TOFF
COUT
-
-
-
-
-
2
0.5
-
IF=5mA, VL=10V
50V; f=1MHz
ms
pF
Turn-Off
Output Capacitance
Input Characteristics @ 25°C
Input Control Current
Input Dropout Current
Input Voltage Drop
Reverse Input Current
25
IL=150mA
-
IF
IF
-
-
2
-
mA
mA
V
0.3
0.9
-
0.4
1.2
-
IF=5mA
VR=5V
VF
IR
1.4
10
µA
Load current derates linearly from 150mA @ 25oC to 120mA @ 85oC.
Measurement taken within 1 second of on time.
1
2
R05
2