Molded Mini-DYAD
CM10
Absolute Maximum Ratings are stress ratings. Stresses
in excess of these ratings can cause permanent damage
to the device. Functional operation of the device at these
or any other conditions beyond those indicated in the
operational sections of this data sheet is not implied.
Exposure of the device to the absolute maximum ratings
for extended period may degrade the device and effect
its reliability.
Absolute Maximum Ratings (@ 25˚ C)
Parameter
Min
Typ Max Units
Switching Voltage
CM10 - Molded Mini-DYAD™
Switching Current
-
-
-
-
-
-
-
-
-
200 Volts
0.5 Amps
CM10 - Molded Mini-DYAD™
Carry Current
CM10 - Molded Mini-DYAD™
Switching Frequency
2
Amps
CM10 - Molded Mini-DYAD™
Contact Resistance
500 Hz
CM10 - Molded Mini-DYAD™
-0 100 mΩ
(See detailed specifications for more information.)
Specifications
All parameters are at 25°C unless otherwise stated.
PARAMETER
CONDITIONS
SYMBOL
MIN
TYP
MAX
UNITS
Contact Ratings
Operate ampere turns range
Release ampere turns range
Switching Voltage
Switching Current
Carry Current
Full Blade Tolerance = 1.5NI
Full Blade Tolerance = 1.5NI
Max DC/PeakAC Resistive
Max DC/PeakAC Resistive
Max DC/PeakAC Resistive
Max DC/PeakAC Resistive
AT
AT
VL
IL
IC
-
10
5
-
-
-
-
-
-
-
-
-
30
30
200
500
2.0
10
NI
NI
VDC
mAmps
Amps
VA
Contact Rating
-
Life Expectancy
1V, 10mA Signal Level
10V, 10mA Low Level
-
-
-
-
CR
-
-
-
-
-
-
-
1000
500
2
2
70
-
-
-
-
x106 Ops
-x106 Ops
x106 Ops
x106 Ops
50V, 100mA Telecom Load
100V, 100mA Rated Loads
Static Contact Resistance
Contact Material
50mV, 10mA(1)
100
-
Ω
-
Ru
Switch Specifications
Insulation Resistance(2)
Capacitance
100V, 25°C, 40% RH
Across Open Contacts
Between Contacts
At nominal coil voltage,
10Hz Square Wave
Zener-Diode Suppression(3)
IR
-
-
109
-
250
-
1011
0.3
300
-
-
-
-
Ω
pF
VDC/Peak AC
ms
Dielectric Strength(5)
Operate Time,
including bounce
Release Time
TOP
0.5
TREL
-
-
0.1
ms
Environmental Ratings
Storage Temperature
Operating Temperature
Soldering Temperature
TA
TO
-
-40
-40
-
-
-
-
+125
+125
+265
˚C
˚C
˚C
(1) Contact resistance measured with 4 terminal method, 1.1" between test leads
(2) >1012 Ω is available upon request
(3)
A 24V zener in series with a diode across the coil
(4) Use caution not to exceed vibration resistance limits while ultrasonically cleaning. Contact Clare, Inc.
Engineering for more details/ recommendations
(5) 15 ampere turn minimum
Rev. 1
2
www.clare.com