9/12
DATA SHEET
9. Precautions
1. Handling precaution
(1) Avoid the application of any stress to the encupsulant.
(2) Avoid any contact by a sharp metal nail or other materials with the encupsulant.
encupsulant
φ =4.4mm
(Hatching area)
NG
(3) Pick and Place
Recommend condition : nozzle inner radius ≧φ4.4mm
Bad ex : narrow nozzle
Avoid direct contact to the encapsulant with the nozzle.
(4). PCB handling
Bending the circuit board with soldered LEDs may cause breakage of LEDs.
Please take care to bow, twist, and warpage of fthe PCB.
Cathode mark
2. Lighting at low current
A minimum current value of lighting of all dice is 6mA.
When a minimal current is applied, LED dice may look different in their brightness due to
the individual difference of the LED element, and it is not a failed product.
3. Handling of static electricity
These products are sensitive to static electricity charge.
Please take measure to prevent any static electricity being produced as the wearing of a wristband
or anti-static gloves when handling this product.
All devices, equipment, and machinary must be properly grounded. It is recommended that precautions
be taken against surge voltage to the equipment that mounts the LEDs.
When inspecting the final products in which LEDs were assembled, it is recommended to check
whether the assembled LEDs are damaged by static electricity or not.
It is easy to find static-damaged LEDs by a light-on test.
Symbol
Name
CITILED
CL-L400-MC1W1-A
CITIZEN ELECTRONICS CO.,LTD. JAPAN
Ref.CE-P1578 10/11