6/10
DATA SHEET
6. Reliability
(1) Details of the tests
Test Item
Test Condition
Ta=25 C, IF=720 mA× 1000 hours(with Al-fin)
Ta=80 C, Tj≒120 C, IF=720 mA× 1000 hours(with Al-fin)
-40 C × 1000 hours
Continuous Operation Test
Low Temperature Storage Test
High Temperature Storage Test
Moisture-proof Test
100 C × 1000 hours
60 C, 90 ꢀRH for 1000 hours
Thermal Shock Test
-40 C × 30 minutes – 100 C × 30 minutes, 100 cycle
(2) Judgment Criteria of Failure for Reliability Test
(Ta=25 C)
Measuring Item
Forward Voltage
Total Luminous Flux
Measuring Condition
Judgment Criteria for Failure
Symbol
VF
IF=720mA
> U × 1.1
< S × 0.85
IF=720mA
Φv
U defines the upper limit of the specified characteristics. S defines the initial value.
Note: Measurement shall be taken between 2 hours and 24 hours, and the test pieces should be
returned to the normal ambient conditions after the completion of each test.
CL-L221-C14L1 reliability test results will be used for CL-L233-MC13L1-C.
CITILED
Symbol
Name
CL-L233-MC13L1-C
CITIZEN ELECTRONICS CO.,LTD. JAPAN
Ref.CE-P1095 04/11