欢迎访问ic37.com |
会员登录 免费注册
发布采购

CS5151GDR16 参数 Datasheet PDF下载

CS5151GDR16图片预览
型号: CS5151GDR16
PDF下载: 下载PDF文件 查看货源
内容描述: CPU 4位非同步降压控制器 [CPU 4-Bit Nonsynchronous Buck Controller]
分类和应用: 控制器
文件页数/大小: 14 页 / 309 K
品牌: CHERRY [ CHERRY SEMICONDUCTOR CORPORATION ]
 浏览型号CS5151GDR16的Datasheet PDF文件第2页浏览型号CS5151GDR16的Datasheet PDF文件第3页浏览型号CS5151GDR16的Datasheet PDF文件第4页浏览型号CS5151GDR16的Datasheet PDF文件第5页浏览型号CS5151GDR16的Datasheet PDF文件第7页浏览型号CS5151GDR16的Datasheet PDF文件第8页浏览型号CS5151GDR16的Datasheet PDF文件第9页浏览型号CS5151GDR16的Datasheet PDF文件第10页  
Applications Information: continued  
ing of the output voltage, since the noise associated with  
approximately equal to the maximum on time, resulting in  
a 50% duty cycle. Then, the Gate pin will drive high, and  
the cycle repeats.  
long feedback traces can be effectively filtered.  
Line and load regulation are drastically improved because  
there are two independent voltage loops. A voltage mode  
controller relies on a change in the error signal to compen-  
sate for a deviation in either line or load voltage. This  
change in the error signal causes the output voltage to  
change corresponding to the gain of the error amplifier,  
which is normally specified as line and load regulation. A  
current mode controller maintains fixed error signal under  
deviation in the line voltage, since the slope of the ramp  
When regulator output voltage achieves the 1V level pre-  
sent at the COMP pin, regulation has been achieved and  
normal off time will ensue. The PWM comparator termi-  
nates the switch2on time, with off time set by the COFF  
capacitor. The V  
control loop will adjust switch duty  
cycle as required to ensure the regulator output voltage  
tracks the output of the error amplifier.  
signal changes, but still relies on a change in the error sig-  
2
The soft start and COMP capacitors will charge to their  
final levels, providing a controlled turn on of the regulator  
output. Regulator turn on time is determined by the COMP  
capacitor charging to its final value. Its voltage is limited  
by the soft start COMP clamp and the voltage on the soft  
start pin (see Figures 2 and 3).  
nal for a deviation in load. The V  
method of control  
maintains a fixed error signal for both line and load varia-  
tion, since the ramp signal is affected by both line and load.  
Constant Off Time  
To maximize transient response, the CS5151 uses a con-  
stant off time method to control the rate of output pulses.  
During normal operation, the off time of the high side  
switch is terminated after a fixed period2, set by the COFF  
capacitor. To maintain regulation, the V  
control loop  
varies switch on time. The PWM comparator monitors the  
output voltage ramp, and terminates the switch on time.  
Constant off time provides a number of advantages. Switch  
duty cycle can be adjusted from 0 to 100% on a pulse by  
pulse basis when responding to transient conditions. Both  
0% and 100% duty cycle operation can be maintained for  
extended periods of time in response to load or line tran-  
sients. PWM slope compensation to avoid sub-harmonic  
oscillations at high duty cycles is avoided.  
Switch on time is limited by an internal 30µs timer, mini-  
mizing stress to the power components.  
Trace 1 - Regulator Output Voltage (1V/div.)  
Trace 2 - Inductor Switching Node (2V/div.)  
Programmable Output  
Trace 3 - 12V input (V  
and V ) (5V/div.)  
CC2  
CC1  
Trace 4 - 5V Input (1V/div.)  
The CS5151 is designed to provide two methods for pro-  
gramming the output voltage of the power supply. A four  
bit on board digital to analog converter (DAC) is used to  
program the output voltage from 2.14V to 3.54V in 100mV  
steps, depending on the digital input code. If all four bits  
are left open, the CS5151 enters adjust mode. In adjust  
mode, the designer can choose any output voltage by using  
resistor divider feedback to the VFB and VFFB pins, as in tra-  
ditional controllers. The CS5151 is specifically designed to  
be upwards compatible with the CS5156, which uses a five  
bit DAC code.  
Figure 2: CS5151 demonstration board startup in response to increasing  
12V and 5V input voltages. Extended off time is followed by normal off  
time operation when output voltage achieves regulation to the error  
amplifier output.  
Start Up  
Until the voltage on the VCC1 supply pin exceeds the 3.9V  
monitor threshold, the soft start and gate pins are held low.  
The FAULT latch is reset (no Fault condition). The output  
of the error amplifier (COMP) is pulled up to 1V by the  
comparator clamp. When the VCC1 pin exceeds the monitor  
threshold, the Gate output is activated, and the soft start  
capacitor begins charging. The Gate output will remain on,  
enabling the NFET switch, until terminated by either the  
PWM comparator, or the maximum on time timer.  
If the maximum on time is exceeded before the regulator  
output voltage achieves the 1V level, the pulse is terminat-  
ed. The Gate pin drives low for the duration of the extend-  
ed off time. This time is set by the time out timer and is  
Trace 1 - Regulator Output Voltage (1V/div.)  
Trace 3 - COMP Pin (error amplifier output) (1V/div.)  
Trace 4 - Soft Start Pin (2V/div.)  
Figure 3: CS5151 demonstration board startup waveforms.  
6