Electrical Characteristics: -40¡C ² TA ² 85¡C, 8.0V ² VCC ² 16V unless otherwise specified.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
■ Supply Voltage Section
ICC Supply Current
VCC = 16V, -40¡C, No Load
50
125
mA
V
VCC Normal Operation Range
8.0
13.1
16.0
■ Input Comparator Section
Positive Input Threshold
Input Hysteresis
1.0
2.0
500
-10
3.0
V
mV
µA
kHz
V
200
Input Bias Current *
Input Frequency Range
Input Voltage Range
Output VSAT
0V ² VIN ² 8V
-80
20
0
in series with 1k½
ICC = 10mA
-1
VCC
0.40
10
0.15
V
Output Leakage
VCC = 7V
µA
V
Logic 0 Input Voltage
1
*Note: Input is clamped by an internal 12V Zener.
■ Voltage Regulator Section
Output Voltage
6.25
7.00
7.50
10
V
Output Load Current
mA
mV
mV
dB
Output Load Regulation
Output Line Regulation
Power Supply Rejection
0 to 10 mA
10
20
46
50
8.0V ² VCC ² 16V
150
VCC = 13.1V, 1VP/P 1kHz
34
■ Charge Pump Section
Inverting Input Voltage
Input Bias Current
1.5
1.5
2.0
40
2.5
150
2.5
V
nA
V
Vbias Input Voltage
Non Invert. Input Voltage
Linearity*
2.0
0.7
0.28
10
IIN = 1mA
1.1
V
@ 0, 87.5, 175, 262.5, + 350Hz
@ 350Hz, CT = 0.0033µF, RT = 243k½
IIN = 15µA
-0.10
7
+0.70
13
%
F/VOUT Gain
mV/Hz
I/I
Norton Gain, Positive
Norton Gain, Negative
*Note: Applies to % of full scale (270¡).
0.9
0.9
1.0
1.0
1.1
IIN = 15µA
1.1
I/I
■ Function Generator Section: -40¡C ² TA ² 85¡C, VCC = 13.1V unless otherwise noted.
Differential Drive Voltage
(VCOS+ - VCOS-)
8.0V ² VCC ² 16V
Q = 0¡
5.5
6.5
6.5
7.5
7.5
V
V
V
V
Differential Drive Voltage
(VSIN+ - VSIN-)
8.0V ² VCC ² 16V
Q = 90¡
5.5
Differential Drive Voltage
(VCOS+ - VCOS-)
8.0V ² VCC ² 16V
Q = 180¡
-7.5
-7.5
-6.5
-6.5
-5.5
-5.5
Differential Drive Voltage
(VSIN+ - VSIN-)
8.0V ² VCC ² 16V
Q = 270¡
Differential Drive Current
Zero Hertz Output Angle
Function Generator Error *
8.0V ² VCC ² 16V, TA=25¡C
VCC = 13.1V, TA=25¡C
33
0.0
0
42
1.5
+2
mA
deg
deg
-1.5
-2
Reference Figures 1,2,3,4 Q = 0¡ to 305¡
*Note: Deviation from nominal per Table 1 after calibration at 0¡ and 270¡.
2