Circuit Description and Application Notes  
The CS4101 is specifically designed for use with air-core  
The response time of the F/V is determined by the time  
constant formed by RT and C4. Increasing the value of C4  
will reduce the ripple on the F/V output but will also  
increase the response time. An increase in response time  
causes a very slow meter movement and may be unac-  
ceptable for many applications.  
meter movements. It includes an input comparator for  
sensing an input signal from an ignition pulse or speed  
sensor, a charge pump for frequency to voltage conver-  
sion, a bandgap voltage regulator for stable operation,  
and a function generator with sine and cosine amplifiers  
to differentially drive the motor coils.  
From the simplified block diagram of Figure 5A, the  
input signal is applied to the FREQIN lead, this is the  
input to a high impedance comparator with a typical pos-  
itive input threshold of 3.4V and typical hysteresis of  
0.4V. The output of the comparator, SQOUT, is applied to  
the charge pump input CP+ through an external capaci-  
tor CT. When the input signal changes state, CT is  
charged or discharged through R3 and R4. The charge  
accumulated on CT is mirrored to C4 by the Norton  
Amplifier circuit comprising Q1, Q2 and Q3. The charge  
pump output voltage, F/VOUT, ranges from 2V to 6.3V  
depending on the input signal frequency and the gain of  
the charge pump according to the formula:  
Design Example  
Maximum meter Deflection = 270¡  
Maximum Input Frequency = 350Hz  
1. Select RT and CT  
Q = AGEN ´ ÆF/V  
ÆF/V = 2 ´ FREQ ´ CT ´ RT ´ (VREG Ð 0.7V)  
Q = 970 ´ FREQ ´ CT ´ RT  
Let CT = 0.0033µF, Find RT  
270¡  
RT =  
F/VOUT = 2.0V + 2 ´ FREQ ´ CT ´ RT ´ (VREG Ð 0.7V)  
970 ´ 350Hz ´ 0.0033µF  
RT is a potentiometer used to adjust the gain of the F/V  
output stage and give the correct meter deflection. The  
F/V output voltage is applied to the function generator  
input lead, FGEN. An additional filter circuit can be added  
between F/VOUT and FGEN to reduce needle flutter. The  
output voltage of the sine and cosine amplifiers are  
derived from the on-chip amplifier and function genera-  
tor circuitry. The various trip points for the circuit (i.e., 0¡,  
90¡, 180¡, 270¡) are determined by an internal resistor  
divider, and the bandgap voltage reference. The coils are  
differentially driven, allowing bidirectional current flow  
in the outputs, thus providing up to 305¡ range of meter  
deflection. Driving the coils differentially offers faster  
response time, higher current capability, higher output  
voltage swings, and reduced external component count.  
The key advantage is a higher torque output for the  
pointer.  
RT = 243k½  
RT should be a 250k½ potentiometer to trim out any inac-  
curacies due to IC tolerances or meter movement pointer  
placement.  
2. Select R3 and R4  
Resistor R3 sets the output current from the voltage regu-  
lator. The maximum output current from the voltage reg-  
ulator is 10mA R3 must ensure that the current does not  
exceed this limit.  
Choose R3 = 3.3k½  
The charge current for CT is:  
VREG Ð 0.7V  
= 1.90mA  
3.3k½  
The output angle, Q, is equal to the F/V gain multiplied  
by the function generator gain:  
C1 must charge and discharge fully during each cycle of  
the input signal. Time for one cycle at maximum frequen-  
cy is 2.85ms. To ensure that CT is discharged, assume that  
the (R3 + R4) CT time constant is less than 10% of the  
minimum input frequency pulse width.  
Q = AF/V ´ AFG  
,
where:  
A
FG = 77¡/V (typ)  
T = 285µs  
The relationship between input frequency and output  
angle is:  
Choose R4 = 1k½.  
Q = AFG ´ 2 ´ FREQ ´ CT ´ RT ´ (VREG Ð 0.7V)  
Charge time:  
T = R3 ´ CT = 3.3k½ ´ 0.0033µF = 10.9µs  
or,  
Q = 970 ´ FREQ ´ CT ´ RT  
Discharge time:T = (R3 + R4)CT = 4.3k½ ´ 0.0033µF = 14.2µs  
The ripple voltage at the F/V converterÕs output is deter-  
mined by the ratio of CT and C4 in the formula:  
3. Determine C4  
C4 is selected to satisfy both the maximum allowable rip-  
ple voltage and response time of the meter movement.  
CT(VREG Ð 0.7V)  
ÆV =  
C4  
Ripple voltage on the F/V output causes pointer or nee-  
dle flutter especially at low input frequencies.  
CT(VREG Ð 0.7V)  
VRIPPLE(MAX)  
C4 =  
With C4 = 0.47µF, the F/V ripple voltage is 44mV.  
Figure 7 shows how the CS4101 and the CS-8441 are used  
to produce a speedometer and odometer circuit.  