Electrical Characteristics: 5.5V ² VCC ² 17V; Ð40¡C ² TJ ² +150¡C; Ð40¡C ² TC ² +105¡C; Ð40¡C ² TA ² 105¡C; unless otherwise specified.
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
■
Output Stage
Quiescent Current
IOUT=0mA;
10
mA
ENABLE1=DIRECTION= High
ENABLE2=Low
Output Saturation Voltage
IOUT=2A
3.2
2.6
V
V
I
OUT=500mA
Output Leakage Current
Current Limit
IOUT=0mA
20
µA
A
3.0
■ Logic Control Functions
High Level Input Voltage
Low Level Input Voltage
High Level Input Current
Low Level Input Current
2.0
V
0.8
10
V
µA
µA
µs
-250
Turn on Delay
Guaranteed by design
RLOAD=30½; Coil=5mH;
CLOAD=15pF
50
50
5
5
Turn off Delay
Guaranteed by design
RLOAD=30½; Coil=5mH;
CLOAD=15pF
µs
■
Fault Protection Functions
Overvoltage Shutdown
IOUT = 500mA
18.0
21.5
V
Package Lead Description
PACKAGE LEAD#
LEAD SYMBOL
FUNCTION
15 Lead
Power SIP TO-220
7 Lead
7 Lead
D2PAK
2
4
1
2
1
2
ENABLE1
Enables output when held low and ENABLE 2 = High
DIRECTION Determines the direction of current flow through COIL+ and
COIL- as long as ENABLE1 = Low and ENABLE2 = High
6
3
4
5
6
7
3
4
5
6
7
COIL+
Gnd
Positive Output of H bridge to coil
Ground connection
8
12
10
14
VSS
Supply voltage for IC
COIL-
ENABLE2
Negative Output of H bridge to coil
Enables output when held high and ENABLE 1 = Low
Application Hints
ENABLE1 ENABLE2 DIRECTION COIL+
Motor Direction Control
COIL-
Low
High
OFF
Low
Low
High
X
High
High
X
High
Low
X
High
Low
OFF
OFF
Current flow through the two outputs COIL+ and COIL-
is controlled by the combined settings of ENABLE1,
ENABLE2 and DIRECTION (Table 1). The outputs will be
active only when ENABLE1 is low and ENABLE2 is high.
When DIRECTION is high, current flows out of COIL+
and into COIL-. When DIRECTION is low, current flows
out of COIL- and into COIL+. For any other combination
of ENABLE settings, the outputs are off.
Low
X
OFF
Table 1. Logical Control Diagram
2