Electrical Characteristics: 5.5V ² VCC ² 17V; Ð40¡C ² TJ ² +150¡C; Ð40¡C ² TC ² +105¡C; Ð40¡C ² TA ² 105¡C; unless otherwise specified.  
PARAMETER  
TEST CONDITIONS  
MIN  
TYP  
MAX  
UNIT  
Output Stage  
Quiescent Current  
IOUT=0mA;  
10  
mA  
ENABLE1=DIRECTION= High  
ENABLE2=Low  
Output Saturation Voltage  
IOUT=2A  
3.2  
2.6  
V
V
I
OUT=500mA  
Output Leakage Current  
Current Limit  
IOUT=0mA  
20  
µA  
A
3.0  
Logic Control Functions  
High Level Input Voltage  
Low Level Input Voltage  
High Level Input Current  
Low Level Input Current  
2.0  
V
0.8  
10  
V
µA  
µA  
µs  
-250  
Turn on Delay  
Guaranteed by design  
RLOAD=30½; Coil=5mH;  
CLOAD=15pF  
50  
50  
5
5
Turn off Delay  
Guaranteed by design  
RLOAD=30½; Coil=5mH;  
CLOAD=15pF  
µs  
Fault Protection Functions  
Overvoltage Shutdown  
IOUT = 500mA  
18.0  
21.5  
V
Package Lead Description  
PACKAGE LEAD#  
LEAD SYMBOL  
FUNCTION  
15 Lead  
Power SIP TO-220  
7 Lead  
7 Lead  
D2PAK  
2
4
1
2
1
2
ENABLE1  
Enables output when held low and ENABLE 2 = High  
DIRECTION Determines the direction of current flow through COIL+ and  
COIL- as long as ENABLE1 = Low and ENABLE2 = High  
6
3
4
5
6
7
3
4
5
6
7
COIL+  
Gnd  
Positive Output of H bridge to coil  
Ground connection  
8
12  
10  
14  
VSS  
Supply voltage for IC  
COIL-  
ENABLE2  
Negative Output of H bridge to coil  
Enables output when held high and ENABLE 1 = Low  
Application Hints  
ENABLE1 ENABLE2 DIRECTION COIL+  
Motor Direction Control  
COIL-  
Low  
High  
OFF  
Low  
Low  
High  
X
High  
High  
X
High  
Low  
X
High  
Low  
OFF  
OFF  
Current flow through the two outputs COIL+ and COIL-  
is controlled by the combined settings of ENABLE1,  
ENABLE2 and DIRECTION (Table 1). The outputs will be  
active only when ENABLE1 is low and ENABLE2 is high.  
When DIRECTION is high, current flows out of COIL+  
and into COIL-. When DIRECTION is low, current flows  
out of COIL- and into COIL+. For any other combination  
of ENABLE settings, the outputs are off.  
Low  
X
OFF  
Table 1. Logical Control Diagram  