CP1084
5A Dropout Linear Regulator
Absolute Maximum Ratings (Note 1)
Parameter
Symbol
Min
Max
Unit
o
Operating Junction Temperature Range
T
150
J
C
o
Storage Temperature Range
T
-65
150
300
S
C
o
Lead Temperature (Soldering, 10 sec.)
ESD (Human Body Model)
T
LEAD
C
ESD
2000
V
Note 1: Stresses greater than those listed under "Absolute Maximum Ratings" may cause permanent damage to the
device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond
those indicated under"Recommended Operating Conditions" is not implied. Exposure to "Absolute Maximum
Ratings" for extended periods may affect device reliability.
Recommended Operating Conditions
Parameter
Symbol
Min
Max
Unit
Input Voltage
V
12
V
IN
o
Operating Junction Temperature Range
T
0
125
J
C
* All specs and applications shown above subject to change without prior notice.
1F-5 NO.66 SEC.2 NAN-KAN RD ., LUCHU , TAOYUAN, TAIWAN
Tel:886-3-3214525
Email: server@ceramate.com.tw
Http: www.ceramate.com.tw
Rev 1.0 Jul.6, 2004
Page 4 of 11
Fax:886-3-3521052