欢迎访问ic37.com |
会员登录 免费注册
发布采购

SWTA46501 参数 Datasheet PDF下载

SWTA46501图片预览
型号: SWTA46501
PDF下载: 下载PDF文件 查看货源
内容描述: 数字三相角控制器 [DIGITAL THREE PHASE ANGLE CONTROLLER]
分类和应用: 控制器
文件页数/大小: 6 页 / 385 K
品牌: CELDUC [ celduc-relais ]
 浏览型号SWTA46501的Datasheet PDF文件第1页浏览型号SWTA46501的Datasheet PDF文件第2页浏览型号SWTA46501的Datasheet PDF文件第3页浏览型号SWTA46501的Datasheet PDF文件第5页浏览型号SWTA46501的Datasheet PDF文件第6页  
®
celduc  
S/GRA/SWTA46501/A/23/07/2002  
r
e
l
a
i
s
Page 4/6 GB  
INTERNAL POWER SUPPLY  
CHARACTERISTIC  
LABEL  
VALUE  
INFO.  
Terminals  
3L2 & 5L3  
200->480VAC  
1mA typical  
40-65Hz  
Mains voltage range  
Consumption  
Ue  
Is  
Mains frequency range  
Turn-on time  
F
tm  
100ms  
GENERAL INFORMATION  
Connections  
Power  
Posidriv 2 or 0.8 x 5.5mm  
1.8->3N.m  
Input terminal block  
Screwdriver advised  
Min and max tightening torque  
0.8 x 2mm  
2
Number and cross section of the  
wires  
2 x 1.5->6mm  
2
1 x 2.5mm  
2
(10mm without ferrule)  
Screwdriver for settings  
0.8 x 2mm  
Housing  
Mounting  
Noise level  
Weight  
UL94V0  
Omega DIN rail (DIN50022) or screwed  
Low audible vibrations  
2600g  
STANDARDS  
Standards  
EN60947-4-2 & EN60947-4-3  
IP2L0  
Protection level  
Accordin to V.D.E. 160 part 100 :  
Back hand and finger safety  
Protection against direct touch  
CE marking  
Yes  
UL, cULUS and VDE approvals  
Pending  
STANDARD  
TYPE OF TEST  
LEVEL  
EFFECT  
8kV (air)  
EN61000-4-2  
EN61000-4-3  
EN61000-4-4  
E.S.D. (Electrostatic discharges)  
Radiated electromagnetic fields  
Fast transients bursts  
No effect  
No effect  
No effect  
4kV (touch)  
10V/m  
2kV direct coupling on the power side  
2kV coupling by clamp on the input side  
1kV direct coupling differential mode (input and output)  
2kV direct coupling common mode (input and output)  
EN61000-4-5  
EN61000-4-11  
Electric chocks  
Voltage drop  
No effect  
-
The conducted or radiated disturbances generated by  
solid state relays depend on the wiring and load  
configuration.  
The test method recommended by the European standards  
Radiated and conducted  
disturbances  
NFEN55011 and concerning electromagnetic compatibility leading to  
results far from reality, we decided to advise our customer  
in order to adapt their filtering scheme to their application.  
Please refer to the SVTA – SWTA installation  
manual.