S/MON/SU967460/B/18/11/2008
celpac
page 2 / 7F/GB
Caractéristiques d'entrée / Control characteristics (at 25°C)
Input : Ic = f( Uc)
DC
14
12
Paramètre / Parameter
Tension de commande / Control voltage
Courant de commande / Control current (@ Uc )
Tension de non fonctionnement / Release voltage
LED d'entrée / Input LED
Symbol Min
Typ
Max Unit
Uc
Ic
3,5
<10
2
5-12-24 32
<14 <14
V
mA
V
10
8
Uc off
6
jaune / yellow
4
Tension Inverse / Reverse voltage
Tension de transil d'entrée / Clamping voltage (Transil) Uclamp
Immunité / Input immunity : EN61000-4-4
Urv
32
36
2kV
2KV
V
V
2
0
0
2
4
6
8
10 12 14 16 18 20 22 24 26 28 30 32
Uc (Vdc)
Immunité / Input immunity : EN61000-4-5
Caractéristiques de sortie / Output characteristics (at 25°C)
Paramètre / Parameter
Plage de tension utilisation / Operating voltage range
Tension de crête / Peak voltage
Conditions
Symbol
Ue
Up
Min
24
1200
Typ.
400
Max
600
Unit
V rms
V
Niveau de synchronisme / Zero cross level
Tension amorçage / Latching voltage
Usync
Ua
Ie AC-51
Itsm
Vt
20
10
90
V
V
A rms
A
V
Ie nom
Courant nominal / nominal current (AC-51)
Courant surcharge / Non repetitive overload current
Chute directe à l'état passant / On state voltage drop
Résistance dynamique / On state dynamic resistance
Puissance dissipée (max) /
75
1200
tp=10ms (Fig. 3)
@ 25°C
1000
0,9
4,5
rt
mΩ
2
Pd
0,9x0,9xIe + 0,0045 x Ie
W
Output power dissipation (max value)
Résistance thermique jonction/semelle
Thermal resistance between junction to case
Courant de fuite à l'état bloqué / Off state leakage current
Courant minimum de charge / Minimum load current
Temps de fermeture / Turn on time
Temps d'ouverture / Turn off time
Fréquence utilisation/ Operating frequency range
dv/dt à l'état bloqué / Off state dv/dt
Rthj/c
0,4
0,5
K/W
@Ue typ, 50Hz
Ilk
Iemin
ton max
toff max
f
dv/dt
di/dt
I2t
1
mA
mA
ms
ms
Hz
V/µs
A/µs
A2s
5
@Ue typ, 50Hz
@Ue typ, 50Hz
F mains
10
10
800
0,1
500
50-60
di/dt max / Maximum di/dt non repetitive
I2t (<10ms)
50
5000
7200
Immunité / Conducted immunity level
Immunité / Conducted immunity level
Emission conduite /Conducted & emitted interference
Protection court-circuit / Short circuit protection
IEC/EN61000-4-4 (bursts)
IEC/EN61000-4-5 (surge)
IEC60947-4-3
2kV criterion B
2kV criterion A with external VDR
Class A for Industrial applications
miniature circuit breaker
voir/see page 5
Example
Caractéristiques générales / General characteristics (at 25°C)
Isolement entrée/sortie - Input to output insulation
Isolation sortie/ semelle - Output to case insulation
Résistance Isolement / Insulation resistance
Symbol
Ui
4000
4000
VRMS
VRMS
Ui
Ri
1000 (@500VDC) MΩ
Tenue aux tensions de chocs / Rated impulse voltage
Degré de protection / Protection level / CEI529
Uimp
4000
V
IP20 (with cover or flaps)
Vibrations / Vibration withstand 10 -55 Hz according to IEC 60068-2-6
Tenue aux chocs / Shocks withstand according to IEC 60068-2-27
10/55Hz
Half sinus /11ms
1,5
30
mm
gn
Température de fonctionnement / Ambient temperature (no icing, no
condensation)
-
-40 /+80
°C
Température de stockage/ Storage temperature (no icing, no condensation)
Humidité relative / Ambient humidity
Poids/ Weight
-40/+125
40 to 85
75
°C
%
g
HR
Conformité / Conformity
Conformité / Conformity
plastique du boitier / Housing Material
Semelle / Base plate
EN60947-4-3 (IEC947-4-3)
EN60950 / UL/cUL
PA 6 UL94V0
Aluminium
celduc
www.celduc.com
r
e
l
a
i
s
Rue Ampère B.P. 4
42290 SORBIERS - FRANCE
E-Mail : celduc-relais@celduc.com
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19