S/MON/SO465420/A/16/01/2006
okpac
page 2 / 5F/GB
Uc(V)
8
Caractéristiques d'entrée / Control characteristics (at 25°C)
Typ. Uc=f(Ic)
DC
7
6
Paramètre / Parameter
Plage de courant de commande / Control current range
plage de tension / Voltage range
Symbol Min
Typ
Max
Unit
mA
V
5
Ic
Vc
R
4-20
4
-0,6V
-
150
7,5
3
Impedance d'entrée / Dynamic impedance
LED d'entrée / Input LED
Ω
mΩ
2
1
verte / green
yes
0
Protection Inverse / Reverse polarity protection
Courant maximum / Maximum allowed input current
Ic(mA)
-1
0
8
12 16
-4
4
20 24 28 32 36
Imax
50
mA
Caractéristiques de sortie / Output characteristics (at 25°C)
Paramètre / Parameter
Plage de tension utilisation / Operating voltage range
Tension de crête / Peak voltage
Conditions
Symbol
Ue
Up
Min
200
1200
Typ.
-
Max
480
Unit
V rms
V
V
A rms
A
V
mΩ
W
mA
ms
ms
ms
Hz
V/µs
A/µs
A2s
@ 1mA
Ie nom
voir/ see fig.2
tp=10ms (Fig. 3)
@ 25°C
Tension amorçage / Latching voltage
Ua
20
50
Courant nominal / nominal current (AC-51)
Courant surcharge / Non repetitive overload current
Chute directe à l'état passant / On state voltage drop
Résistance dynamique / On state dynamic resistance
Puissance dissipée (max) / Output power dissipation (max)
Courant de fuite à l'état bloqué / Off state leakage current
Temps d'initialisation / init time
Temps de retard / delay time
Temps de reponse / rise, fall time
Fréquence utilisation/ Operating frequency range
dv/dt à l'état bloqué / Off state dv/dt
di/dt max / Maximum di/dt non repetitive
I2t (<10ms)
Ie AC-51
Itsm
Vt
0,1
550
720
0,9
12
rt
Pd
Ilk
ti
td max
tr max
f
dv/dt
di/dt
I2t
0,9x0,9xIe + 0,012xIe2
@Ue typ, 50Hz
@ switch on 50Hz
@ 50Hz
@ 50Hz , dUl=63%
f mains
1
100
20
63
40
500
50-60
70
50
1500
2500
Immunité / Conducted immunity level
Immunité / Conducted immunity level
Protection surtension interne / Internal overvoltage protection
Protection court-circuit / Short circuit protection
IEC/EN61000-4-4 (bursts)
IEC/EN61000-4-5 (surge)
Varistor 510V
4kV criterion B
4kV criterion B
820(@1mA)
Uclamp
V
voir/ see page 6
Example Fuse Ferraz gRC 25A/32A/50A
Caractéristiques générales / General characteristics (at 25°C)
Isolement entrée/sortie - Input to output insulation
Isolation sortie/ semelle - Output to case insulation
Résistance Isolement / Insulation resistance
Ui
Ui
Ri
4000
4000
1000 (@500VDC)
VRMS
VRMS
MΩ
Tenue aux tensions de chocs / Rated impulse voltage
Degré de protection / Protection level / CEI529
Degré de pollution / Pollution degree
Uimp
4000
IP20
2
V
-
Vibrations / Vibration withstand 10 -55 Hz according to CEI68
Tenue aux chocs / Shocks withstand according to CEI68
Résistance thermique jonction/semelle Thermal resistance junction to case
Température de fonctionnement / Ambient temperature (no icing, no condensation)
Température de stockage/ Storage temperature (no icing, no condensation)
Humidité relative / Ambient humidity
1,5
30/50
0,45
-40 /+100
-40/+125
mm
g
K/W
°C
°C
%
-
Rthj/c
-
HR
40 to 85
Poids/ Weight
65
g
Conformité / Conformity
Conformité / Conformity
plastique du boitier / Housing Material
Semelle / Base plate
EN60947-4-3 (IEC947-4-3)
VDE0805/EN60950 UL/cUL
PA 6 UL94VO
Aluminium, nickel-plated
celduc
www.celduc.com
r
e
l
a
i
s
Rue Ampère B.P. 4
42290 SORBIERS - FRANCE
E-Mail : celduc-relais@celduc.com
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19