celduc
S/CON/SCI0251700/B/25/09/08
r
e
l
a
i
s
Page 4/5 UK
PRELIMINARY DATA
GENERAL INFORMATION
Connections
Power
Philips™ NR2
1.8 N.m
Control
Philips™ NR1
0.8 N.m
Screwdriver advised
Min and max tightening torque
Insulated crimp terminals
(round tabs, eyelet type)
M5
M3
Green LED
(indicates relay has switched ON)
Display
Housing
Mounting
Noise level
Weight
UL94V0
See mounting
sheet
2 screws (M4x12mm)
No audible noise
100g
STANDARDS
Standards
IEC60947-1
IP00
Protection level
Protection against direct touch
CE marking
None
Yes
UL, cULUS and VDE approvals
Pending
STANDARD
TYPE OF TEST
LEVEL
EFFECT
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-11
E.S.D. (Electrostatic discharges)
Radiated electromagnetic fields
Fast transients bursts
Electric chocks
Pending
Pending
Pending
Pending
-
?
?
No effect
?
Voltage drop
Radiated and conducted
disturbances
NFEN55011
Pending