P/P3S-P4S/B/08/01/2016
page 2 / 6 GB
Application category 3 according EN 13849-1
Block diagram P3S version
Block diagram P3S version
SIL2
Power supply
P3S sensors chaining
Use moreover a safety adapted power supply.
Connection cable and connector version outputs (P3S only):
Connection
+24VDC
Cable version
Brown : BN
Blue : BU
Connector version
Pin N°1
0VDC
Pin N°3
I1 ( + output 1)
O1 (- output 1)
I2 (+ output 2)
O2 (- output 2)
Grey : GY
Black : BK
Pink : PK
Pin N°7
Pin N°4
Pin N° 6
White : WH
Pin N°2
- In case of chaining several sensors, consider the products on-
state resistance and the cable resistance. The direct drop by sen-
sor will depend on this resistance and the load current. Typically
we can connect in series 32 products with 2-meters length ca-
bles.
- In case of using standard M12 extension, check carefully the
wire colors concordance.
- These sensors can also be associated to safety modules. Check
the compatibility.
www.celduc.com
r
e
l
a
i
s
5, Rue Ampère BP30004 42290 SORBIERS - FRANCE
E-mail : celduc-relais@celduc.com
Fax +33 (0) 4 77 53 85 51
Service Commercial France Tél. : +33 (0) 4 77 53 90 20
Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tél. +33 (0) 4 77 53 90 19