NR8501 SERIES
OUTLINE DIMENSIONS (Units in mm)
CP/CR
FP/FR
Optical Fiber
ø0.9
ø0.9
Optical Fiber
Length: 1 m MIN
Length: 1 m MIN
ø3.2±0.2
ø7.0±0.2
ø5.0±0.2
8.0±0.3
ø7.0±0.2
2.2
14.0±1.0
ø0.45±0.05
ø2.2
ø0.45±0.05
16.0±0.2
12.7±0.2
17.0±0.2
PIN CONNECTIONS
PIN CONNECTIONS
P.C.D. = ø2.0
4–R1.25±0.2
3
3
P.C.D. = ø2.0
2
1
1
2
3
7.0±0.2
1
2
3
1. Anode (Negative)
2. Cathode (Positive)
3. Case
1. Anode (Negative)
2. Cathode (Positive)
3. Case
2
1
2–ø2.5
8.5±0.2
12.0±0.15
OPTICAL FIBER CHARACTERISTICS
PARAMETER
SPECIFICATION
UNITS
SMF
GI-50 Fiber
Mode Field Diameter
Core Diameter
9.5±1
−
50±3
125±2
2
µm
µm
µm
%
-
125±2
2
Cladding Diameter
Maximum Cladding Noncircularity
Maximum Core/Cladding Concentricity
Outer Diameter
1.6
4.0
%
0.9±0.1
1100 to 1270
30
0.9±0.1
-
mm
nm
mm
Cut-off Wavelength
Minimum Fiber Bending Radius
Fiber Length
30
1000 MIN
1000 MIN mm
Flammability
UL1581 VW-1
35±2 mm
8.99±0.5 mm
Connector