NE34018
ABSOLUTE MAXIMUM RATINGS1 (TA = 25°C)
TYPICAL NOISE PARAMETERS (TA = 25°C)
SYMBOLS
PARAMETERS
UNITS
RATINGS
FREQ.
(MHz)
NFOPT
(dB)
GA
ΓOPT
(dB)
MAG
ANG
Rn/50
VDS
VGDO
VGSO
IDS
Drain to Source Voltage
Gate to Drain Voltage
Gate to Source Voltage
Drain Current
V
V
4
-3
VDS = 2 V, IDS = 10 mA
900
2000
2500
3000
3500
4000
.56
.63
.68
.70
.76
.82
20.5
16.3
14.1
13.6
12.3
11.6
.76
.61
.49
.39
.28
.20
30
41
51
49
71
80
.45
.28
.18
.16
.12
.10
V
-3
mA
°C
°C
mW
IDSS
TCH
TSTG
PT
Channel Temperature
Storage Temperature
Total Power Dissipation
125
-65 to +125
150
Note:
VDS = 2 V, IDS = 30 mA
1. Operation in excess of any one of these parameters may result
in permanent damage.
2000
2500
3000
.60
.70
.76
17.0
15.3
14.2
.56
.43
.32
39
46
50
.23
.15
.26
VDS = 3 V, IDS = 20 mA
900
2000
2500
3000
3500
4000
4500
.56
.62
.66
.70
.80
.84
.90
20.2
16.8
14.9
14.0
13.2
12.8
11.0
.74
.62
.56
.45
.36
.29
.20
26
42
50
65
76
85
98
1.54
.43
.31
.24
.14
.10
.08
TYPICAL PERFORMANCE CURVES (TA = 25°C)
TOTAL POWER DISSIPATION
vs. AMBIENT TEMPERATURE
200
FREE AIR
150
100
50
R
TH = 833˚C/W
20˚C
Ambient Temperature, TA (˚C)
125˚C
0
200
100
150
50