欢迎访问ic37.com |
会员登录 免费注册
发布采购

CAT1021RE-45TE13 参数 Datasheet PDF下载

CAT1021RE-45TE13图片预览
型号: CAT1021RE-45TE13
PDF下载: 下载PDF文件 查看货源
内容描述: 监控电路,带有I2C串行2K位CMOS EEPROM ,手动复位及看门狗定时器 [Supervisory Circuits with I2C Serial 2k-bit CMOS EEPROM, Manual Reset and Watchdog Timer]
分类和应用: 电源电路电源管理电路光电二极管监控可编程只读存储器电动程控只读存储器电可擦编程只读存储器
文件页数/大小: 20 页 / 149 K
品牌: CATALYST [ CATALYST SEMICONDUCTOR ]
 浏览型号CAT1021RE-45TE13的Datasheet PDF文件第5页浏览型号CAT1021RE-45TE13的Datasheet PDF文件第6页浏览型号CAT1021RE-45TE13的Datasheet PDF文件第7页浏览型号CAT1021RE-45TE13的Datasheet PDF文件第8页浏览型号CAT1021RE-45TE13的Datasheet PDF文件第10页浏览型号CAT1021RE-45TE13的Datasheet PDF文件第11页浏览型号CAT1021RE-45TE13的Datasheet PDF文件第12页浏览型号CAT1021RE-45TE13的Datasheet PDF文件第13页  
CAT1021, CAT1022, CAT1023  
SDA when SCL is HIGH. The CAT1021/22/23 monitor  
the SDA and SCL lines and will not respond until this  
condition is met.  
EMBEDDED EEPROM OPERATION  
The CAT1021/22/23 feature a 2kbit embedded serial  
EEPROM that supports the I2C Bus data transmission  
protocol.ThisInter-IntegratedCircuitBusprotocoldefines  
any device that sends data to the bus to be a transmitter  
and any device receiving data to be a receiver. The  
transfer is controlled by the Master device which  
generates the serial clock and all START and STOP  
conditions for bus access. Both the Master device and  
Slavedevicecanoperateaseithertransmitterorreceiver,  
but the Master device controls which mode is activated.  
STOP Condition  
A LOW to HIGH transition of SDA when SCL is HIGH  
determinestheSTOPcondition.Alloperationsmustend  
with a STOP condition.  
DEVICE ADDRESSING  
The Master begins a transmission by sending a START  
condition.TheMastersendstheaddressoftheparticular  
slave device it is requesting. The four most significant  
bitsofthe8-bitslaveaddressareprogrammableinmetal  
and the default is 1010.  
I2C Bus Protocol  
The features of the I2C bus protocol are defined as  
follows:  
(1) Data transfer may be initiated only when the bus is  
not busy.  
The last bit of the slave address specifies whether a  
ReadorWriteoperationistobeperformed.Whenthisbit  
is set to 1, a Read operation is selected, and when set  
to 0, a Write operation is selected.  
(2) During a data transfer, the data line must remain  
stable whenever the clock line is high. Any changes in  
thedatalinewhiletheclocklineishighwillbeinterpreted  
as a START or STOP condition.  
After the Master sends a START condition and the slave  
address byte, the CAT1021/22/23 monitors the bus and  
responds with an acknowledge (on the SDA line) when  
its address matches the transmitted slave address. The  
CAT1021/22/23 then perform a Read or Write operation  
depending on the R/W bit.  
START Condition  
The START Condition precedes all commands to the  
device, and is defined as a HIGH to LOW transition of  
Figure 3. Bus Timing  
t
t
t
F
HIGH  
R
t
t
LOW  
LOW  
SCL  
t
t
HD:DAT  
SU:STA  
t
t
t
t
HD:STA  
SU:DAT  
SU:STO  
SDA IN  
BUF  
t
t
DH  
AA  
SDA OUT  
Figure 4. Write Cycle Timing  
SCL  
SDA  
8TH BIT  
BYTE n  
ACK  
t
WR  
STOP  
CONDITION  
START  
CONDITION  
ADDRESS  
Doc No. 3009, Rev. K  
9