Mechanical
TopView
Bottom View
NOTES:
All measurements are in inches
FAN MOUNTED ON COVER ADDS 1.70”.
COOLING: The KX750 is designed to operate with 30 CFM airflow in 50°C ambient termperature.
SHOCK AND VIBRATION: The KX750 meets the requirements of MIL-STD-810D. (Vibration-Method 514.3 Procedure I; Shock-Method 516.3 Procedure I).
WEIGHT: Approximately 6 lbs.
Connector Specifications
Pin Specifications
J9 Connector
Molex No. 22-08--1140
Terminal Block 1
Terminal Block 2
POS
FUNCTION
AC Line
POS
FUNCTION
PIN
1
FUNCTION
1
2
3
1
2
3
4
-V2
+V2
-V3
+V3
- Remote Sense #2
+ Remote Sense #2
Current Sense Bus #2
- Remote Sense #3
+ Remote Sense #3
Curent Sense Bus #3
+ Remote Sense #1
- Remote Sense #1
Sync I/O
AC Neutral
Ground
2
3
4
5
6
7
8
9
10
11
12
13
14
AC Power Fail Alarm
Status/Control Return
DC Power Good
Remote Inhibit
Current Sense Bus #1
Standard Options are shown, consult factory for other available options.
The information provided herein is believed to be reliable; however, C&D TECHNOLOGIES assumes no responsibility for inaccuracies or omissions. C&D TECHNOLOGIES assumes no responsibility
for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change without notice. No patent rights or licenses to any
of the circuits described herein are implied or granted to any third party. C&D TECHNOLOGIES does not authorize or warrant any C&D TECHNOLOGIES product for use in life support devices/systems
or in aircraft control applications.
Page 4