Output Voltages and Maximum Rated Loads
OUTPUT #1
OUTPUT #2
OUTPUT #3
MODEL NUMBER
VOUT
IMAX
VNOM
12V
IMAX
20A
20A
VNOM
IMAX
KX750-F3A
5V
100A
12V
20A
KX750-F2B
KX750-F1C
5V
5V
100A
100A
12V
NOTE:Total power not to exceed 750 watts.
Output Specifications
Parameter
Limits
Regulation
Main Output
Outputs #2 - 3
Line
+0.1%
+0.2%
+0.4%
+0.2%
Load
+0.2%
Cross
+0.2%
Minimum Load
Output #1
Outputs #2 & #3
Hold-UpTime
5.0A
1.0A
>20mSec at Full Load
Parameter
Conditions
Min
Typ
Max
Units
Voltage Adustment Range
Nominal line on all outputs
5
%
PARD
20 MHz bandwidth
1
% P-P
Temperature
Operating
0
50
-20
0
50
70
°C
°C
Derates 20W/°C
Storage
+85
95
°C
Humidity Range
Non-condensing
%
Temperature Coefficient (TC)
All outputs after half hour warm-up
0.02
%/°C
KX750 4/99 REV B
Page 3