Mechanical
TOP VIEW
NOTES:
All measurements are in inches
FAN MOUNTED ON COVER ADDS 1.80”. A 1.3”FAN IS ALSO AVAILABLE.
COOLING: The KX500 is designed to operate with 30 CFM airflow.
SHOCK ANDVIBRATION: The KX500 meets the requirements of MIL STD-810D. (Vibration-Method 514.3 Procedure I; Shock-Method 516.3 Procedure I).
WEIGHT: Approximately 5 lbs.
Connector Specifications
Pin Specifications
Terminal Block 1
Terminal Block 2
J3 Connector
J3 Connector
POS
FUNCTION
AC Line
POS
1
FUNCTION
PIN
1
FUNCTION
+ Sense
- Sense
Molex No.
22-05-3021
1
2
3
+V4
-V4
Connector
AC Neutral
Ground
2
2
3
+V5
J5 Connector
J5 Connector
4
-V5
1
2
3
4
5
AC Power Good
Signal Common
DC Power Good
Remote Inhibit
Molex No.
5
+V3
Connector
22-28-1050
6
-V3
7
+V2
8
-V2 & -FAN
+ FAN OUTPUT
Remote Inhibit Rtn.
9
Model Number Specification
KX500 -
*
B
*
L
H
H
N
N denotes no
Base Model
active current
sharing available
Output Voltage
Configuration (see
table on pg. 3 for options)
H denotes that a logic level “1”
indicates DC OK (transition
“B” denotes Class B EMI
to “0” on loss of output regulation)
compliance (standard feature)
Cover Options: C denotes plain cover;
F denotes cover w/integral fan
N denotes no cover
H denotes that a logic level “1”
indicates AC present.
(transition to “0” on loss of AC power)
L denotes that a logic level “1’ (or open) enables the
power supply (short to signal common - or -sense
inhibits the output)
Standard Options are shown, consult factory for other available options.
Page 4
KX500 8/99 REV B