ELECTRICAL SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
NOMINAL
INPUT
VOLTAGE
(VDC)
RATED
OUTPUT
VOLTAGE
(VDC)
RATED
OUTPUT
CURRENT
(mA)
INPUT CURRENT
REFLECTED
RIPPLE
CURRENT
(mAp-p)
NO LOAD RATED LOAD
EFFICIENCY
(%)
MODEL
(mA)
(mA)
HPR100
HPR101
HPR102
HPR103
HPR104
HPR105
5
5
5
5
5
5
5
12
15
±5
±12
±15
150
62
50
±75
±30
±25
20
20
20
20
20
20
216
212
212
218
212
200
10
5
5
5
5
69
70
71
68
68
75
5
HPR106
HPR107
HPR108
HPR109
HPR110
HPR111
12
12
12
12
12
12
5
12
15
±5
±12
±15
150
62
50
±75
±30
±25
10
10
10
10
10
10
90
81
81
88
81
81
5
5
5
5
5
5
69
77
77
71
74
77
HPR112
HPR113
HPR114
HPR115
HPR116
HPR117
15
15
15
15
15
15
5
12
15
±5
±12
±15
150
62
50
±75
±30
±25
8
8
8
8
8
8
72
72
72
72
63
63
5
5
5
5
5
5
69
69
69
69
76
79
HPR118
HPR119
HPR120
HPR121
HPR122
HPR123
24
24
24
24
24
24
5
12
15
±5
±12
±15
150
62
50
±75
±30
±25
8
8
8
8
8
8
48
48
45
45
45
45
15
15
15
15
15
15
65
65
69
69
67
69
Note: Other input to output voltages may be available. Please contact factory.
COMMON SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT
Voltage Range
4.5
10.8
13.5
21.6
5
5.5
VDC
VDC
VDC
VDC
12
15
24
13.2
16.5
26.4
Voltage Rise Time
See Typical Performance Curves & Application Notes: "Capacitive Loading Effects on Start-Up of DC/DC Converters"
ISOLATION
RatedVoltage
TestVoltage
Resistance
Capacitance
LeakageCurrent
750
750
VDC
Vrms(1060pk)
GΩ
60 Hz, 10 Seconds
10
25
2
100
8.5
pF
µArms
VISO=240VAC,60Hz
OUTPUT
RatedPower
VoltageSetpointAccuracy
Ripple & Noise
750
mW
%
mVp-p
mVrms
mVp-p
RatedLoad, NominalVIN
BW = DC to 10MHz
BW =10Hz to 2MHz
BW = DC to 10MHz
±5
45
30
90
HPR103
Voltage (Over Input Voltage Range)
1mA Load, VOUT = 5V
1mA Load, VOUT = 12V
1mA Load, VOUT = 15V
7
15
18
VDC
VDC
VDC
%/°C
TemperatureCoefficent
.01
1
REGULATION
LineRegulation
High Line to Low Line
%/%Vin
GENERAL
SwitchingFrequency
Frequency Change
PackageWeight
170
24
2
kHz
%
g
OverLineandLoad
MTTF per MIL-HDBK-217, Rev. E*
GroundBenign
FixedGround
NavalSheltered
AirborneUninhabitedFighter
CircuitStressMethod
TA=+25°C
7.9
1.9
1.2
MHr
MHr
MHr
kHr
TA=+35°C
TA=+35°C
TA=+35°C
300
TEMPERATURE
Specification
Operation
-25
-40
-40
+25
+85
+100
+110
°C
°C
°C
Storage
*FordemonstratedMTTFresultsreference PowerConvertiblesReliabilityReportHPR105
Page 2
HPR1XX REV K 8/01