Input Specifications
Parameter
Conditions
Min
Typ
Max
Units
Operating Range
DC
36
48
72
VDC
Inrush Current Limiting
36VDC
72VDC
25
50
APK
APK
%
Efficiency
48VDC at full load
70
Transient Response
Remote Sense
The peak output voltage excursion will not exceed 2% and
will recover within 1% in 200 µsec for a 25% load step
change.
Remote Sense is provided on Output #1 and will
compensate for 0.7V of line drop. Remote Sense leads
are protected against open, short and reversal.
Over Temperature Protection
Thermal switch turns off power supply if overheating occurs
and automatically restarts.
Remote On/Off (Optional)
The power supply is turned on with aTTL logic‘1’(or open)
signal and turned off by a switch closure or TTL logic ‘0’
referenced to (-) sense terminal.
Safety
Safety Certified to UL/CUL to 1950, File Number E131694.
TUV to EN60950/IEC 950.
Over Voltage Protection
Output #1: 6.5V 0.5 VDC.
The power supply will latch off until AC power is cycled.
Cooling
The unit is designed to operate with 30 CFM of airflow.
Over Current Protection
Individual current limit on all outputs. Automatic recovery
upon fault removal.
Active Inrush Current Limiting
Inrush current is independent of ambient temperature.
Page 2
DNX350 4/2002 REV B