Mechanical
TOPVIEW
0.040
COVER
1.95
8.50
0.25
0.55
1
TB2
3.90
4.85
1
J9
OUTPUT NO. 1
1
5V RETURN
9.00
TB1
5V
6-32 THD 4 PLC’S
Maximum depth of mounting
scres is 0.156 inches
NOTES:
All measurements are in inches
FAN MOUNTED ON COVER ADDS 1.30”.
COOLING: The DNX301 is designed to operate with 30 CM airflow.
SHOCK ANDVIBRATION: The DNX301 meets the requirements of MIL STD-810D.
WEIGHT: Approximately 3 lbs.
J9 Connector
Terminal Block 1
Terminal Block 2
Molex No. 22-28-1090
POS
FUNCTION
POS
FUNCTION
1
2
3
DC +
1
2
3
4
5
6
-V2
PIN
FUNCTION
DC -
+V2
1
+ Sense
Ground
-V3
2
- Sense
+V3
3
N/C
-V4
4
N/C
+V4
5
Start Up Sync.
N/C
6
7
Remote Inhibit
Current Share
Control Signal Rtn
8
9
Page 4
DNX301 4/2002 REV B