BUCCANEER FOR POWER
400 Series Buccaneer
SPECIFICATION
Electrical:
Mechanical:
Sealing:
IP68, EN 60529 tested @ 1.054kg/sq cm
(15lb/sq in) 10m depth for 2 weeks
Poles:
2, 3
8A
4, 6, 8
5A
10, 12
1A
Current Rating:
Cable Acceptance:
3.0 - 7.0mm
Voltage Rating:
250Vac/dc
125Vac/dc
50Vac/dc
Contact Accommodation:
2, 3 pole, 20 - 24 AWG
4, 6, 8 pole, 22 - 26 AWG
10, 12 pole, 24 - 28 AWG
Contact Resistance:
Insulation Resistance:
AC Breakdown Voltage:
<5mΩ
6
>10 MΩ (@ 500V d.c.)
Termination:
Crimp, solder and PCB
2.5kV
Insertion/Withdrawal Force:
No. poles:
Operating Temperature:
Flex and panel types
Overmoulded
2
3
4
6
8
10
12
–40°C to +80°C
–20ºC to +85ºC
Insertion Force (typ):
Withdrawal Force (typ):
19N 25N 27N 27N 28N 55N 62N
12N 17N 17N 21N 22N 25N 29N
Approvals:
UL:
Tightening Torques:
Panel mount (PX0412)
Rear fixing nut:
E214972
1273303
40002226
Pending
CSA:
VDE:
CCC:
1.0-1.1Nm (9lbf.in.)
1.0-1.1Nm (9lbf.in.)
Panel mount (PX0413)
Front fixing nut:
Overmoulded cable assemblies approvals to
customer requirements.
Cable Retention force:
3mm dia
60N
80N
4.7mm dia
Rear panel thread PX0412:
Panel thread PX0413:
M16x1.5
Material:
18.97x26TPI Whitworth form to BS84 med fit
Flex and panel types:
Body Mouldings:
Flammability Rating:
UV Resistance:
Polyamide
UL94V-0
To EN 50021:1999
Dimensions:
Overmoulded types:
Body Mouldings:
Overall dimensions of connectors when mated together
Polyurethane
UL94V-HB
Flammability Rating:
Flex + Flex In-Line
80mm
Dia. over coupling ring
19.1mm
Contacts:
Copper alloy, Gold plated
O Rings:
Nitrile
Panel Sealing O Ring:
Nitrile
Compliant
www.elektron-bulgin.com