occurs faster than the 10ns indicated by tCKCH, then there is  
a chance that some digital feedthrough may be coupled onto  
the hold capacitor. This could cause a small offset error for  
that particular conversion.  
Figure 4 shows the typical method for placing the A/D into  
the power-down mode. If CONV is kept LOW during the  
conversion and is LOW at the start of the 13 clock cycle,  
then the device enters the power-down mode. It remains in  
this mode until the rising edge of CONV. Note that CONV  
must be HIGH for at least tACQ in order to sample the signal  
properly as well as to power-up the internal nodes.  
Thus, there are two basic ways to operate the ADS7834.  
CONV can be synchronous to CLK and CLK can be con-  
tinuous. This would be the typical situation when interfacing  
the converter to a digital signal processor. The second  
method involves having CONV asynchronous to CLK and  
gating the operation of CLK (a non-continuous clock). This  
method would be more typical of an SPI-like interface on a  
microcontroller. This method would also allow CONV to be  
generated by a trigger circuit and to initiate (after some  
delay) the start of CLK. These two methods are covered  
under DSP Interfacing and SPI Interfacing.  
There are two different methods for clocking the ADS7834.  
The first involves scaling the CLK input in relation to the  
conversion rate. For example, an 8MHz input clock and the  
timing shown in Figure 3 results in a 500kHz conversion  
rate. Likewise, a 1.6MHz clock would result in a 100kHz  
conversion rate. The second method involves keeping the  
clock input as close to the maximum clock rate as possible  
and starting conversions as needed. This timing is similar to  
that shown in Figure 4. As an example, a 50kHz conversion  
rate would require 160 clock periods per conversion instead  
of the 16 clock periods used at 500kHz.  
POWER-DOWN TIMING  
The conversion timing shown in Figure 3 does not result in  
the ADS7834 going into the power-down mode. If the  
conversion rate of the device is high (approaching 500kHz),  
then there is very little power that can be saved by using the  
power-down mode. However, since the power-down mode  
incurs no conversion penalty (the very first conversion is  
valid), at lower sample rates, significant power can be saved  
by allowing the device to go into power-down mode be-  
tween conversions.  
The main distinction between the two is the amount of time  
that the ADS7834 remains in power-down. In the first mode,  
the converter only remains in power-down for a small  
number of clock periods (depending on how many clock  
periods there are per each conversion). As the conversion  
rate scales, the converter always spends the same percentage  
of time in power-down. Since less power is drawn by the  
digital logic, there is a small decrease in power consump-  
tion, but it is very slight. This effect can be seen in the  
typical performance curve “Supply Current vs Sample Rate.”  
tCVL  
tCVCK  
CONV  
tCKCS  
tCKCH  
14  
15  
16  
1
2
3
4
11  
12  
13  
14  
15  
16  
1
CLK  
(1)  
tCKDE  
tCKDD  
D11  
(MSB)  
D0  
(LSB)  
DATA  
D10  
D9  
D2  
D1  
tACQ  
tCVHD  
tCKSP  
SAMPLE/HOLD  
MODE  
SAMPLE  
HOLD  
tCONV  
SAMPLE  
HOLD  
(2)  
INTERNAL  
CONVERSION  
STATE  
(
3)  
IDLE  
IDLE  
CONVERSION IN PROGRESS  
NOTES: (1) Clock periods 14 and 15 are shown for clarity, but are not required for proper operation of the ADS7834, provided that the  
minimum tACQ time is met. The CLK input may remain HIGH or LOW during this period. (2) The transition from sample mode to hold  
mode occurs on the falling edge of CONV. This transition is not dependent on CLK. (3) The device remains fully powered when  
operated as shown. If the sample time is longer than 3 clock periods, power consumption can be reduced by allowing the device to  
enter a power-down mode. See the power-down timing for more information.  
FIGURE 3. Basic Conversion Timing.  
ADS7834  
SBAS098A  
9
www.ti.com