PARALLEL OUTPUT (During a Conversion)
READING DATA
After conversion ‘n’ has been initiated, valid data from con-
version ‘n – 1’ can be read and will be valid up to 7µs after
the start of conversion ‘n’. Do not attempt to read data from
7µs after the start of conversion ‘n’ until BUSY (pin 26) goes
HIGH; this may result in reading invalid data. Refer to Table
IV and Figures 3 to 5 for timing specifications.
The ADS7805 outputs full or byte-reading parallel data in
Binary Two’s Complement data output format. The parallel
output will be active when R/C (pin 24) is HIGH and CS (pin
25) is LOW. Any other combination of CS and R/C will tri-
state the parallel output. Valid conversion data can be read
in a full parallel, 16-bit word or two 8-bit bytes on pins 6-13
and pins 15-22. BYTE (pin 23) can be toggled to read both
bytes within one conversion cycle. Refer to Table III for ideal
output codes and Figure 2 for bit locations relative to the
state of BYTE.
Note! For the best possible performance, data should not be
read during a conversion. The switching noise of the asyn-
chronous data transfer can cause digital feedthrough de-
grading the converter’s performance.
The number of control lines can be reduced by tying CS LOW
while using R/C to initiate conversions and activate the
output mode of the converter (see Figure 3).
DIGITAL OUTPUT
BINARY TWO’S COMPLEMENT
DESCRIPTION
ANALOG INPUT
±10V
BINARY CODE
HEX CODE
Full-Scale Range
SYMBOL
DESCRIPTION
Convert Pulse Width
MIN TYP MAX UNITS
Least Significant
Bit (LSB)
305µV
t1
t2
40
7000
8
ns
Data Valid Delay after R/C LOW
µs
+Full Scale
9.999695V
0111 1111 1111 1111
7FFF
(10V – 1LSB)
t3
t4
BUSY Delay from R/C LOW
BUSY LOW
65
8
ns
µs
Mid-scale
0V
0000 0000 0000 0000
1111 1111 1111 1111
0000
FFFF
t5
BUSY Delay after
End of Conversion
220
ns
One LSB below
Mid-scale
–305µV
t6
t7
Aperture Delay
Conversion Time
40
ns
µs
µs
ns
ns
µs
–Full Scale
–10V
1000 0000 0000 0000
8000
7.6
8
2
Table III. Ideal Input Voltages and Output Codes.
t8
Acquisition Time
t9
Bus Relinquish Time
BUSY Delay after Data Valid
10
35
83
PARALLEL OUTPUT (After a Conversion)
t10
t11
50 200
7.4
After conversion ‘n’ is completed and the output registers
have been updated, BUSY (pin 26) will go HIGH. Valid data
from conversion ‘n’ will be available on D15-D0 (pins 6-13
and 15-22). BUSY going HIGH can be used to latch the data.
Refer to Table IV and Figures 3 to 5 for timing specifications.
Previous Data Valid
after R/C LOW
t7 + t6
t12
Throughput Time
R/C to CS Setup Time
Time Between Conversions
9
10
83
µs
ns
µs
ns
10
t13
10
t14
Bus Access Time
and BYTE Delay
10
TABLE IV. Conversion Timing.
BYTE LOW
BYTE HIGH
+5V
6
7
23
22
21
20
19
18
17
16
15
6
7
23
22
21
20
19
18
17
16
15
Bit 15 (MSB)
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 7
Bit 6
Bit 0 (LSB)
Bit 1
Bit 8
Bit 9
ADS7805
ADS7805
8
8
Bit 5
9
9
Bit 2
Bit 4
Bit 10
Bit 11
Bit 12
Bit 13
Bit 14
10
11
12
13
14
10
11
12
13
14
Bit 3
Bit 3
Bit 4
Bit 2
Bit 5
Bit 1
Bit 8
Bit 6
Bit 0 (LSB)
Bit 7
Bit 15 (MSB)
FIGURE 2. Bit Locations Relative to State of BYTE (pin 23).
ADS7805
8
SBAS020D
www.ti.com