TYPICAL PERFORMANCE CURVES
Typical at +25°C and ±15VDC power supplies, unless otherwise noted.
INPUT STAGE SUPPLY CURRENT
vs OUTPUT VOLTAGE
12
ISOLATION LEAKAGE CURRENT
vs ISOLATION VOLTAGE
5
4
3
2
Max at 70°C
10
Max at 25°C
8
Typ at 70°C
Typ at 60Hz
6
Typ at 25°C
Typ at 25°C
4
Typ at DC
3mA
1
0
2
0
1.2mA
–15
–10
–5
Output Voltage (V)
Add 2mA typ, 4mA max for 3652
0
5
10
15
0
0
1
1
2
3
4
5
6
Isolation Voltage (kV)
at V–
at V+
NORMALIZED LINEARITY vs TEMPERATURE
REJECTION vs RESISTOR IMBALANCE
1.5
1.4
1.3
1.2
160
120
IMR 60Hz
CMR 60Hz
G =100
G =1
G =100
G =100
3650
3652
3650
80
40
1.1
1
G =1
G =1
3652
–25
0
25
50
75
100
0.25
0.50
Input Resistor Imbalance
RG1 RG2
RG1 + RG2 RG1 + RG2
0.75
1
Temperature (°C)
or
DISTORTION vs FREQUENCY
GAIN ERROR vs FREQUENCY
10
3
2
0
VOUT = +10V
Gain = 1
RL = 2kΩ
–2
–4
1
Gain = 100
0.3
–6
–8
0.1
0.1
3
1
3
10
3
10
30
Frequency (kHz)
Frequency (kHz)
®
4
3650/52