INSTALLATION AND  
DISCUSSION  
OPERATING INSTRUCTIONS  
OUTPUT CURRENT RATINGS  
At rated output voltage accuracy, the 722 is capable of  
providing 64mA divided among its four outputs(1). A minimum  
average output current of 3mA is recommended at each  
output to maintain voltage accuracy.  
Typical application connections for the 722 are shown in  
Figures 1 and 2. Primary power (VIN) is applied at the P+ and  
Vterminals. The common or ground for VIN may be con-  
nected to either P+ or V; the only requirement is that P+ and  
V+ must be positive with respects to V.  
Output channels(2) can be connected in series or parallel for  
higher output voltage or current.  
Power for the internal oscillator and switch drivers is derived  
from the primary power by a voltage dropping resistor, R1.  
The value of R1 as a function of VIN is shown in the Typical  
Characteristics section. Alternately, voltage for the V+ termi-  
nal can be obtained from a separate source. V+ should be  
+5V to +7.5V positive with respect to V. If a separate source  
is used, the V+ input must be applied before the P+ input in  
order to avoid possible damage to the unit. P+ and V+ must  
remain positive with respect to Vat all times (including  
transients). If necessary, diode clamps should be attached  
across these inputs.  
ISOLATION CONFIGURATIONS  
The fact that the two outputs of the 722 are isolated from the  
input and from each other allows both two-port and three-port  
isolation connections.  
Figure 1 shows TIs 3650 optically coupled isolation amplifier  
connected in three-port configuration. One of the 722 chan-  
nels provides power to the 3650 input. The other channel  
supplies power to the 3650 output. The amplifier input and  
output are isolated from each other and the system power  
supply common. In this configuration, the 722 channel-to-  
channel isolation specification applies to the amplifier input-  
to-output voltage.  
The E pin enables the converter when connected to V+ and  
disables it when connected to V.  
An external capacitor, C (0.47µF ceramic), is used to reduce  
input ripple. It should be connected as close to the P+ and V–  
pins as practical. Input leads to these terminals should also  
be kept as short as possible. External shielding may be  
appropriate in applications where RFI at the 900kHz nominal  
oscillator frequency is a problem because the 722 is not  
internally shielded.  
+15V  
+VO1 P+  
R1  
C1  
C
V+  
E
VO1  
+VO2  
C2  
VIN  
Each output is filtered with an internal 0.22µF capacitor.  
Output ripple voltage can be reduced below the specified  
value by adding external capacitors up to 10µF between  
each output and its common.  
Com  
O/P  
I/P Com  
Com  
VO2 V–  
722  
Power  
Supply  
Common  
FIGURE 1. Three-Port Isolation.  
NOTES: (1) Outputdenotes a single output terminal (+V or V) and its  
associated common. (2) Channeldenotes a pair of outputs (+V and V) and  
their associated common.  
722  
6
SBVS016A  