SPECIFICATIONS  
ELECTRICAL  
Specifications apply between solder tabs.  
100MS  
TYP  
PARAMETER  
CONDITIONS  
MIN  
MAX  
UNITS  
Isolation Voltage  
Rated Continuous, DC  
Rated Continuous, AC  
Test  
Capacitance  
Resistance  
3500  
2000  
8000  
VDC  
Vrms  
VDC  
pF  
µA  
10 Seconds  
120V, 60Hz  
5
1010  
0.23  
Leakage Current  
NOTE: Temperature changes (T/t) greater than 1°C per minute below 0°C and long term storage above 100°C are not recommended.  
PACKAGE INFORMATION(1)  
PACKAGE DRAWING  
MODEL  
PACKAGE  
NUMBER  
100MS  
EMI Shield  
124  
NOTE: (1) For detailed drawing and dimension table, please see end of data  
sheet, or Appendix D of Burr-Brown IC Data Book.  
20k  
2MΩ  
2MΩ  
10  
APPLICATIONS INFORMATION  
MULTIPLE DEVICE ORIENTATION  
6
100kΩ  
11  
13  
G = 100  
9
2
7
3
14  
VOUT  
1
15  
12  
A typical application for the 100MS is shown in Figure 3.  
Using multiple devices within 30mm of each other can  
cause them to interact by forming beat frequency interfer-  
ence outputs. The 100MS can reduce this interference by as  
much as a factor of 200:1 depending on the distance be-  
tween the devices and their relative orientation.  
3656  
16  
Power  
C(1) C(1)  
Supply  
17  
19.6kΩ  
20  
Common  
19  
C(1)  
Thermocouple #1  
+VCC  
Minimum EMI results when the gaps of both shields are  
paralleled as in Figure 3a.  
20kΩ  
2MΩ  
2MΩ  
10  
®
6
100kΩ  
11  
13  
Gap in Shield  
G = 100  
9
2
7
3
14  
VOUT  
2
15  
12  
100MS  
3656  
16  
C(1) C(1)  
Power  
Supply  
Common  
17  
19.6kΩ  
20  
®
19  
Gap in Shield  
C(1)  
100MS  
Thermocouple #2  
+VCC  
NOTE: (1) C = 0.47µF.  
(a) Optimum PCB Layout.  
FIGURE3b.IsolatedDataAcquisitionInputCircuitry.Orien-  
tation for Minimum EMI.  
FIGURE 3a. Optimum PCB Layout. Orientation for mini-  
mum EMI.  
The information provided herein is believed to be reliable; however, BURR-BROWN assumes no responsibility for inaccuracies or omissions. BURR-BROWN assumes  
no responsibility for the use of this information, and all use of such information shall be entirely at the user’s own risk. Prices and specifications are subject to change  
without notice. No patent rights or licenses to any of the circuits described herein are implied or granted to any third party. BURR-BROWN does not authorize or warrant  
any BURR-BROWN product for use in life support devices and/or systems.  
®