Isolated and Regulated 3 WATT Modular DC/DC Converters  
asd03 erieꢀ  
INPUT sPECIFICaTIONs  
GENERaL sPECIFICaTIONs  
Input Voltage Ranges:  
12 VDC Nominal  
24 VDC Nominal  
48 VDC Nominal  
PI Type  
9-18 VDC  
18-36 VDC  
36-72 VDC  
Input-Output Isolation  
500VDC (“M” Versions)  
1500VDC (“H” Versions)  
10-9nth Ohm min.  
Isolation Resistance  
Switching Frequency  
Conducted EMI  
Safety  
Input Filter  
100Khz  
Meets EN55022 Class B  
UL, cUL - “H” Versions Only  
OUTPUT sPECIFICaTIONs  
Voltage and Current  
Load Regulation  
See Selection Chart  
Single (10% to FL)  
Dual (25% to FL)  
(HL-LL)  
ENVIRONMENTaL sPECIFICaTIONs  
+/- 0.5%  
+/-1%  
Oper. Temperature  
Case Temperature  
Storage Temperature  
Cooling  
-25 to +71°C  
Line Regulation  
+/- 0.5%  
100°C max.  
Temperature Coefficient  
Ripple/Noise(Single/Dual)  
+/-0.05%/°C  
3.3V/5V  
100mVp-p max.  
12V/15V  
-40 to +100°C *  
Free Air Convection  
1,203,000 Hrs.  
MTBF Single O/P  
Dual O/P  
1% p-p max.  
1,145,000 Hrs.  
Voltage Accuracy  
Short Circuit Protection  
Voltage Balance (Dual)  
Efficiency  
+/- 2%  
MIL-HDBK-217F  
Ground Benign, 25°C  
Continuous  
+/-1%  
See Selection Chart  
PHYsICaL sPECIFICaTIONs  
Case Material  
Black coated Copper  
w. Non-conductive base  
Fully Encapsulated  
0.5 oz, (13g)  
Construction  
Weight  
Dimensions  
1.25” x 0.8” x 0.5”  
All specifications are typical at nominal input, full load, and 25DegC unless  
otherwise noted  
Astrodyne products are not authorized or warranteed for use  
as critical components in life support systems, equipment used  
in hazardous environments, nuclear controls systems, or other  
mission-critical applications.  
* These are stress ratings. Exposure of the devices to any of these conditions  
may adversely affect long term reliability. Proper operation under conditions  
other than the standard operating conditions is neither warranteed nor implied.  
300 Myleꢀ stꢁnꢂiꢀh Blvꢂ., Tꢁunton, Ma 02780  
WWW.asTROdYNE.COM  
Ph: 1-800-823-8082  
Fꢁx: 508-823-8181