100W Medical Adapters for Health Care Applications with PFC  
AHP101 series  
PHYSICAL SPECIFICATIONS  
INPUT SPECIFICATIONS  
Size  
5.75” x 2.99” x 1.69”  
(146 x 76 x 43mm)  
Desktop Style  
Input Voltage Range  
90-260 VAC (100-240 Nominal)  
Frequency Range (Sine Wave) 47-63 Hz  
Construction  
Input Current  
Low Line (100VAC)  
1.2A max.  
0.5A max.  
Weight  
23.63oz (670g)  
See Selection Chart  
UL94V-1  
High Line (240VAC)  
0.5W  
Output Connector  
Flammability Rating  
No Load Power Consumption  
Inrush Current, typ (Cold Start) Low Line (100VAC)  
High Line (240VAC)  
50A max.  
120A max.  
Leakage Current (240Vin, 60hHz) 0.25mA max.  
ENVIRONMENTAL SPECIFICATIONS  
Power Factor Correction  
Protection Class  
0.95 min.  
Class I  
Oper. Temperature  
-10 to +40°C (FL) *  
50% Load @ 70°C  
(See Derate Curve Last Page)  
Free Air Convection  
OUTPUT SPECIFICATIONS  
Cooling  
Storage Temperature  
Operating/Storage Humidity  
EMC  
-40 to +85°C, 10~95% RH *  
0% to 95%, non-cond *  
Compliance to EN55011 (CISPR11),  
EN61000-3-2, -3 Class B  
100,000 Hrs  
Voltage and Current  
See Selection Chart  
Output Power Range  
Load Regulation (Note 2)  
Line Regulation (Note 1)  
Over Load Protection*  
Over Voltage Protection*  
Short Circuit Protection  
Transient Response  
0 to FL Rating, 100W max.  
± 5%, max. (0-FL, 230Vin)  
± 1%, max., FL  
MTBF (MIL-HDBK-217F)  
Surge Voltage  
110-150%, Auto Recovery  
112-132%  
2kV  
ESD - Air  
IEC61000-4-2, 8kV  
Auto Recovery  
ESD - Contact  
IEC61000-4-2, 6kV  
110Vin, FL to 1/2L  
±0.04%/°C, typ  
4mS  
Operating Altitude (Elevation)  
Vibration  
3000m  
Temperature Coefficient  
Ripple/Noise (Note 3)  
Start Up / Hold Up Time  
5G, 10 ~ 500Hz, 10min./1cycle,  
60min. each along X, Y, Z axes  
100mV p-p  
100Vin, FL  
2S max. / 16mS min.  
NOTES  
GENERAL SPECIFICATIONS  
1. Line regulation is defined by changing ±10% of input voltage from  
nominal line at rated load.  
Input-Out Isolation  
Input-GND Isolation  
Isolation Resistance  
Efficiency(FL, Nom. Vin)  
Safety  
4000 VAC  
1500 VAC  
2. Load regulation is defined by changing ±40% of measured output  
load from 60% rated load.  
50MΩ, 500VDC,25°XC/ 70% RH  
See Selection Chart  
3. Ripple & noise is measured by using 20MHz bandwidth limited  
oscilloscope and terminated each output with a 0.47uF capacitor at  
rated load and nominal line.  
ANSI/AAMI ES 60601-1:2005  
(UL/cUL 3rd Edition),  
EN 60601-1:2006  
(TUV/T-mark 3rd Edition)  
All specifications are typical at nominal input, full load, and 25°C unless other-  
wise noted  
* These are stress ratings. Exposure of the devices to any of these conditions  
may adversely affect long term reliability. Proper operation under conditions  
other than the standard operating conditions is neither warranteed nor implied.  