APA06 Non-Isolated Power SIPs
3V-5.5V Input, 1.2V-3.3V Output, 9-20W Output
Absolute Maximum Rating
Characteristic
Min
Typ
Max
6
Units
Vdc
Vdc
°C
Notes
Input Voltage(continuous)
Input Voltage(peak/surge)
Operating temperature
storage temperature
7
100ms non-repetitive
200LFM
-25
-40
55
125
°C
AVN20 Series Output Characteristics
Characteristic
Min
Typ
Max
Units
Notes
Power
APA06K04( E-6 )
7.2
9
W
W
APA06M04( E-6 )
APA06Y04( E-6 )
APA06D04( E-6 )
APA06G05( E-6 )
APA06F05( E-6 )
10.8
12.6
15
W
W
W
19.8
6
W
Output Current
A
Line Regulation
Load Regulation
Efficiency
0.5
1
%Vo
%Vo
Io=6A
Io=0~6A, Vin=5V
APA06K04( E-6 )
76
79
81
84
86
87
78
81
83
86
88
89
%
%
%
%
%
%
APA06M04( E-6 )
APA06Y04( E-6 )
APA06D04( E-6 )
APA06G05( E-6 )
APA06F05( E-6 )
Dynamic Response
25-50% load
50
100
50
100
9
70
200
100
200
10.8
+1
mV
µs
Ta=25°C, di/dt =1A/10µs
Ta=25°C, di/dt =1A/10µs
Ta=25°C, di/dt =1A/10µs
Ta=25°C, di/dt =1A/10µs
50-25% load
mV
µs
Current Limit Threshold
Output Setpoint Voltage
Trim Range
6.6
-1
A
0
%Vo
%Vo
Vo%
%Vo/°C
mV
Vin=5V, Io=6A
84
116
Sense Compensation
Temperature Coefficient
Ripple (p-p)
16
25
0.02
50
( 0 to 20MHz BW )
( 0 to 20MHz BW )
Noise (p-p)
50
mV
Switching Frequency
450
kHz
-4-
USA
1-760-930-4600
1-760-930-0698
Europe
44-(0)1384-842-211
44-(0)1384-843-355
Asia
852-2437-9662
852-2402-4426
TEL:
FAX:
www.astec.com