Technical Reference Notes
AA60A-036L-050D033H Series
(5V / 3V3 Dual Output Half Brick)
Electrical Specifications (continued)
INPUT SPECIFICATION
Parameter
Device
Symbol
Min
Typ
Max
Unit
Operating Input Voltage
All
VIN
19
18
36
60
60
VDC
VDC
After start-up with max 60W
Startup Voltage
All
All
19
20
VDC
Shutdown Voltage
17
-
17.8
-
18
6.5
VDC
A
Maximum Input Current3
IIN,max
Conditions: VIN = V
IN,min
IO = IO,max; TA = 25 ºC
Input Reflected Ripple Current4
Conditions: PO1 = PO2 = 30W; TA = 25 ºC
All
All
II1/ II2
-
-
-
100
-
mA PK-PK
Standing Loss
-
3
W
Condition: VIN = VIN,nom; TA = 25 ºC
NOTE: 3. This power module is not internally fused. An input line is recommended.
4. See Figure 1 for Input Reflected Ripple Current Test Setup.
OUTPUT SPECIFICATIONS
Parameter
Device
Symbol
Min
Typ
Max
Unit
Voltage Setpoint
All
VO1/ VO2
4.92 / 3.25
5.0 / 3.30
5.08 / 3.35
Vdc
Conditions: V = VIN,nom; TA = 25 ºC;
I
TC = 50ºC; VO1: IO1 = IO,max; VO2:
IO2 = IO,min
;
Load Current
All
All
IO1/IO2
0.5 / 0.5
-
12.0 / 15.0
10,000
A
Output Capacitive Load
?F
Line Regulation
Load Regualtion5
All
All
-
-
0.01
0.05
1.0
1.0
%Vo
%Vo
Temperature Coefficient of Voltage
All
-
-
2.0
%Vo
Conditions: TC = -40?C to 100?C
VIN =VIN,nom; IO = IO,max
;
MODEL: AA60A-036L-050D033H SERIES
OCTOBER 10, 2002 - REVISION A
SHEET 3 OF 12