欢迎访问ic37.com |
会员登录 免费注册
发布采购

IMP1-2Y0-1E0-1E0-1L0-1Q0-4NN0-00-A 参数 Datasheet PDF下载

IMP1-2Y0-1E0-1E0-1L0-1Q0-4NN0-00-A图片预览
型号: IMP1-2Y0-1E0-1E0-1L0-1Q0-4NN0-00-A
PDF下载: 下载PDF文件 查看货源
内容描述: [IMP CONFIGURABLE POWER SUPPLY]
分类和应用:
文件页数/大小: 14 页 / 3925 K
品牌: ARTESYN [ ARTESYN TECHNOLOGIES ]
 浏览型号IMP1-2Y0-1E0-1E0-1L0-1Q0-4NN0-00-A的Datasheet PDF文件第1页浏览型号IMP1-2Y0-1E0-1E0-1L0-1Q0-4NN0-00-A的Datasheet PDF文件第2页浏览型号IMP1-2Y0-1E0-1E0-1L0-1Q0-4NN0-00-A的Datasheet PDF文件第3页浏览型号IMP1-2Y0-1E0-1E0-1L0-1Q0-4NN0-00-A的Datasheet PDF文件第5页浏览型号IMP1-2Y0-1E0-1E0-1L0-1Q0-4NN0-00-A的Datasheet PDF文件第6页浏览型号IMP1-2Y0-1E0-1E0-1L0-1Q0-4NN0-00-A的Datasheet PDF文件第7页浏览型号IMP1-2Y0-1E0-1E0-1L0-1Q0-4NN0-00-A的Datasheet PDF文件第8页浏览型号IMP1-2Y0-1E0-1E0-1L0-1Q0-4NN0-00-A的Datasheet PDF文件第9页  
IMP  
ENVIRONMENTAL SPECIFICATIONS  
Operating temperature  
Storage temperature  
Electromagnetic susceptibility  
Humidity  
-40 °C to 70 °C ambient. Derate each output 2.5% per degree from 50 °C to 70 °C. (-20 °C start up)  
-40 °C to +85 °C  
Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3  
Operating; non-condensing 10% to 95% RH  
Vibration  
IEC68-2-6 to the levels of IEC721-3-2  
MTBF demonstrated  
> 550,000 hours at full load, 220 Vac and 25 °C ambient conditions  
OUTPUT MODULE LINE-UP  
Triple  
36 W  
2 A  
Module Code  
Module Type  
1
2
3
5
4
Dual  
Single  
210 W  
35 A  
Single  
360 W  
60 A  
Single  
750 W  
150 A  
Single  
1500 W  
300 A  
Max output power  
144 W  
10 A  
Max output current  
Output voltages available  
Standard voltage increments  
2 to 60 V 2 to 60 V 2 to 60 V 2 to 60 V  
2 to 28 V  
16  
2 to 28 V  
18  
25  
25  
25  
18  
V1  
V2  
Yes  
No  
V1,V2,V3  
No  
Remote sense  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
Remote margin  
No  
V-Program - I2C Control  
Active Current Share  
Module Inhibit - I2C Control  
Module Inhibit - Analog  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
Yes  
No  
Yes  
No  
Overvoltage/Overcurrent  
protection  
Yes  
Yes  
Minimum load required  
No  
1
No  
2
No  
3
No  
4
No  
No  
No  
1
Slots occupied in any iMP  
case  
1
4
advancedenergy.com